Colasit CHVN 315-710 Operating Manual

Colasit CHVN 315-710 Operating Manual

High pressure – plastic industrial fan

Advertisement

Quick Links

OPERATING MANUAL
High pressure – Plastic industrial fan
Agent:
For use in Ex zones
Page 1
TD-000 799-E
Edition 11/2022, Subject to alteration
Copyright by COLASIT AG Spiez
Not for use in Ex zones
Phone +41 (0)33 655 61 61
CHVN 315 - 710
COLASIT AG
Plastics construction
CH-3700 Spiez
Fax +41 (0)33 654 81 61

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CHVN 315-710 and is the answer not in the manual?

Questions and answers

Summary of Contents for Colasit CHVN 315-710

  • Page 1 For use in Ex zones Not for use in Ex zones Page 1 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61 ●...
  • Page 2 Preface This operating manual is the driver's license for operation of this COLASIT fan. It is the main source of information and also the safety guideline. It deserves your full attention - please read it carefully. The contents of this operating manual are subject to change without notice in order to take technical progress into account.
  • Page 3: Table Of Contents

    17.2 Assembly instructions for CHVN 315-710 with V-belt drive ................ 20 Spare parts lists ............................22 18.1 Spare parts list for CHVN 315-710 with direct drive ..................22 18.2 Spare parts list CHVN 315-710 with V-belt drive ..................23 Part 3: Certificates ..............................24 Certificates ..............................
  • Page 4: Part 1: General

    Definition The term "COLASIT fan" stands for a Swiss high-quality product and contains all the components and individual parts as specified in the purchase order or in the material parts list, which, when assembled, form a functional unit.
  • Page 5: Safety Review

    COLASIT only guarantees the durability of materials on condition that technological data was available before production. Any change in the conditions of use is only permissible after approval by COLASIT; otherwise this will entail loss of warranty. Any changes or repair work during the warranty period may only be made by our fitters or with our written consent.
  • Page 6: General Risk Matrix

    Page 6 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61 ●...
  • Page 7: Eu And Uk Conformity Of The Colasit Fan

    Explosion protection COLASIT plastic fans are suitable for the conveyance of gases in Zone 1 or 2 (Equipment Category 2 or 3) depending on the model. COLASIT plastic fans are not suitable for the conveyance of gases in Zone 0 (Equipment Category 1).
  • Page 8: Fan Ex Marking

    T4: Max. surface temp. 135 °C Gb/Gc Equipment Protection Level (EPL) Page 8 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61 ●...
  • Page 9: Correct Installation Of Atex Fan

    (10mm mesh) to be provided by the customer. Connection ducting on the pressure side must be routed to prevent the backflow of foreign bodies, rainwater or condensate into the fan. To ensure this, please use the COLASIT condensate drain nozzles. Page 9...
  • Page 10: Commissioning, Initial Startup, Test Run

    The motor electrical specifications are indicated on the motor’s rating plate or in the motor manufacturer’s data sheet. When speed is controlled by means of a frequency converter, the maximum speed is limited by COLASIT to the value indicated on the manufacturer’s rating plate.
  • Page 11: Electrical Installations

    An internal procedure instruction regulates the work to be carried out as well as the preparatory work for re- commissioning (e.g. cleaning). Page 11 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61 ●...
  • Page 12: Putting Out Of Operation

    • Check all screw unions for firm seating. Page 12 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61 ●...
  • Page 13 If possible, use water and a household cleaning agent. Page 13 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61 ●...
  • Page 14: Spare Parts

    You will find important instructions on how to produce process instructions in various chapters of this operating manual. To help ensure the safe operation of the fan, COLASIT offers the service of reviewing process instructions prepared by the operator. Logbook For your own safety and as an aid to personal responsibility, we recommend the keeping of a logbook for the entire period during which the fan is in service.
  • Page 15: Troubleshooting

    Bearing was excessively greased. above. Dust in bearing. Renew seal. Page 15 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61 ●...
  • Page 16: Retrofittable Original Accessories

    - Motor cover for outdoor installation - Splinter protection Fan identification The following rating plate is affixed to each COLASIT fan: Manufacturer Field for CE / UKCA marking and applicable standards ATEX identification, for details see the section on Explosion Protection Fan specifications: fan type, casing design, material of casing and impeller, order number and date of manufacture.
  • Page 17: Dimensional Drawings

    Dimensional drawings 16.1 Dimensions of the CHVN 315-710 with direct drive Page 17 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61...
  • Page 18: Dimensions Of The Chvn 315-710 With V-Belt Drive

    16.2 Dimensions of the CHVN 315-710 with V-belt drive Page 18 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61...
  • Page 19: Assembly Instructions

    Assembly instructions 17.1 Assembly instructions CHVN 315-710 with direct drive 1. Attach support steel sheets including round steel plate and motor to base frame 2. Place plastic back plate and impeller onto shaft with TaperLock bush and tighten 3. Join casing with round steel plate together with bolts 4.
  • Page 20: Assembly Instructions For Chvn 315-710 With V-Belt Drive

    17.2 Assembly instructions for CHVN 315-710 with V-belt drive 1. Attach support steel sheets including round steel plate, pedestal bearing and shaft to base frame. 2. Place plastic back plate and impeller onto shaft with TaperLock bushing and tighten. 3. Join casing with round steel plate together with bolts 4.
  • Page 21 Dismantle in the reverse order of steps. Page 21 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61 ●...
  • Page 22: Spare Parts Lists

    Spare parts lists 18.1 Spare parts list for CHVN 315-710 with direct drive Base frame Back plate Support construction Impeller with Taper-Lock bushing (fixed bore for ATEX) Motor plate and hub cap Casing Motor Support bracket Front steel plate Round steel plate...
  • Page 23: Spare Parts List Chvn 315-710 With V-Belt Drive

    18.2 Spare parts list CHVN 315-710 with V-belt drive Base frame Support bracket Support construction Front steel plate Motor plate with bracket Base rails Pedestal bearing Sliding rails Shaft Motor Shaft protection V-belt protection steel plate Round steel plate V-belt pulley complete...
  • Page 24: Part 3: Certificates

    Name and address of the person authorised to COLASIT AG compile the relevant technical documentation: Faulenbachweg 63 CH-3700 Spiez Central Fans Colasit Ltd East Moons Moat Unit 12A Palmers Road Authorized person or position: Redditch - Worcestershire, B98 0RF United Kingdom...
  • Page 25: Atex Declaration Of Conformity

    Eurofins CML New Port Road, Ellesmere Port, CH65 4LZ, UK COLASIT hereby certifies compliance with the basic health and safety requirements for the design and manufacture of equipment and protection systems for use for their intended purpose in explosive atmospheres in compliance with regulation UKEX S.I.
  • Page 26 This certificate may only be copied in full without any changes Page 26 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61 ●...
  • Page 27: Further Certificates

    Datasheet of the fan If ATEX version additionally: • ATEX Certification/Inspection report for fan (see 19.2) • ATEX Certification/Inspection report for electric motor (if this was supplied by COLASIT) Page 27 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration...
  • Page 28: Form For The Correct Assembly Of Atex Fans

    Name of fitter: ........................... Place and date:..........................Signature: ............................Page 28 COLASIT AG TD-000 799-E Plastics construction Edition 11/2022, Subject to alteration CH-3700 Spiez Copyright by COLASIT AG Spiez Phone +41 (0)33 655 61 61 Fax +41 (0)33 654 81 61 ●...

Table of Contents