Read these instructions before connecting the actuator. Damage caused by non compliance of
these instructions is not covered by our warranty.
J4M Electric actuators operate with the use of live electricity. It is recommended that only qualified electrical
engineers be allowed to connect or adjust these actuators.
VOLTAGE TO BE CONNECTED
All our actuators model S2 to S40 are ready to work from 24-240 VDC/VAC.
All our actuators model B2 to B40 are ready to work at 12 VDC/VAC ONLY.

ELECTRICAL CONNECTORS

Warning: Before connecting ensure that the voltage to be applied to the actuator is within the range shown on the
identification label. The supplied electrical connectors, used to connect to the actuator are DIN plugs. Ensure the
diameter of cable to be used conforms to the maximum and minimum requirements of the DIN plugs to maintain
water tightness (Fig.1).
Connector
Model
J4M 2 to 10
J4M 25 to 40
Warning: Ensure that the square rubber seal is in place
when fixing each DIN plug to the actuator. Failure to do
so could allow water ingress and damage caused by this
installation error will invalidate any warranty. The DIN
plugs are fixed to their respective bases on the actuator
housing with a screw. Do not over tight the screw (8)
when assembling (Max. 0.5Nm ).
1. Gasket
2. Terminal strip
3. Cable fixing screws
4. Housing
5. Washer
Small Black
Din43650/C
min. Ø
max. Ø
5 mm
--
6. Grommet
7. Gland - nut
8. Fixing screw
9. Washer
10. Gasket
min. Ø
6 mm
8 mm
--
8 mm
HANDBOOK / J4M SERIES
Big Grey or Black
EN175301-803 Form A
max. Ø
10,5 mm
10,5 mm
7