Icing Up / Condensation On Side Panels; Build-Up Of Ice At A Single Point - Siemens KG39EAI43 Repair Manual

Table of Contents

Advertisement

Fault Diagnosis
Fault

Icing up / condensation on side panels

Build-up of ice at a single point

2020-08-03_58300000002379_ara_en_p
Possible cause
Humidity above 80 %, insufficient ventilation between
the side panels, particularly in side-by side appliances
(refrigerator and freezer are set up together)
Foaming failure due to trapped air in the separating
wall between refrigerator and freezer compartment
Drain gutter or hole for condensation water blocked or
covered
Copyright by BSH Hausgeräte GmbH
Troubleshooting
Required tools:
Insulation mat
non flammable
1. Install insulation mat (1).
2. Cut insulation mat (2).
Replace appliance.
Wipe back panel with detergent solution.
[20000786]