3. Ice separating (drop) mode
status of
ice tray
Ice separation start
level SW
8~11sec
normal
level SW
motor
CW
revolution
10 sec
level SW
error
1) Time of each zone used to verify level switch error
2) The rotation of motor is sensed at each zone
3) In case of level switch error, ice separation is done by time.
4) If ice separating motor has error, the mode stop.
4. Water supply mode
N
CONTENTS
MAX1.1sec
8.5~12.2sec
CCW
11 sec
START
Water supply valve ON
Water flow Pulse Count = 0
1sec passed after
water valve ON ?
Y
Water flow Pulse > 10
Y
Flow-Sensor Error mode operation
Water flow Pulse spec
〉Pulse spec
N
water supply time 〉time spec
Y
water supply valve OFF
END
22
Horizontal position
0.2sec
CW
STOP
1.1 sec
N
N
Y
REMARKS