Description
World warm air hand dryer is a surface-mounted ADA (American Disabilities Act) compliant dryer powered by a universal
brushed motor, and delivers up to 950 watts of drying power. These models operate at all voltages 115 – 230VAC,
incorporate an integrated heating element, blower speed control and infrared sensor for automatic activation. Your
specific model may include a high efficiency particulate absorption (HEPA) filter to remove a minimum of 99.97% of
contaminants at 0.3 microns in size or larger. These models are intended for use in commercial, industrial, office and
public facility environments.

Electrical Specifications

Table 1
Models
Type
Q-XXXXX
Automatic

General Safety Information

This appliance is not intended for use by young children or persons with physical, sensory or mental
disabilities unless adequately supervised by a responsible person to ensure they can use the appliance safely.
Young children should be supervised to ensure they do not play with the appliance.
DANGER
injury or death from electric shock.
• Always disconnect the power source before servicing or installing the hand dryer.
DANGER
• This hand dryer must be properly grounded for safe operation. An identified ground connection point is supplied on the
hand dryer's wall base.
• We recommend GFCI protection in wet or damp locations or as required by local code.
WARNING
recommendations are not followed.
• Installation and servicing should only be performed by qualified electrical technicians.
• Use only the electrical power (voltage and frequency) specified for the model hand dryer being installed. See Table 1 -
Electrical Specifications.
• Connect the hand dryer to the nearest suitable distribution panel. The fixed wiring must include a disconnection means
complying with local wiring codes.
• To limit a voltage drop, and insure efficient operation, use No.14 AWG wire or larger as required by local electrical codes.
• Always connect to a branch circuit with circuit breaker or fuse protection with an electrical rating greater than the model
hand dryer's rated amperage shown in Table 1 - Electrical Specifications in accordance with required local electrical
codes such as NEC (National Electrical Code) and/or CEC (Canadian Electrical Code).
• To avoid a hazard due to inadvertent resetting of the thermal cutout, the hand dryer must not be supplied through an
external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.
• Each automatic model hand dryer must have a dedicated circuit.
• Route all field wiring away from moving parts within the hand dryer.
• Use fittings with smooth, rounded surfaces for protection of power supply cables as required by local electrical codes
such as The NEC (National Electrical Code) and/or CEC (Canadian Electrical Code).
CAUTION
• Follow the mounting height recommendations in Table 2.
• On a stud wall, one side of the hand dryer should be mounted to an existing stud.
Electrical Ratings
115 / 208 / 230 VAC 950W 50/60Hz
Failure to disconnect the power source before installation or servicing can result in serious
Failure to properly ground this unit could result in severe electrical shock and/or death.
Risk of fire, personal injury or property damage are possible if local codes, or safety
Improper mounting could result in personal injury or property damage.
Certifications
cETLus, CE, IP24