Rexroth IndraDrive Supply Units HMV01
Technical Properties
5.2.8

X33, Acknowledge Messages of Integrated Mains Contactor

Function, Pin Assignment
Input EIN2
If the supply unit is operated with an additional mains contactor,
the signal at the input EIN2 (X32.4) must be switched to level "L"
within the tolerated mains failure time, when this additional mains
contactor is switched off.
See also "F2819 Mains failure" in the firmware documentation
"Troubleshooting Guide"
Data
Number of poles
Type
Design
Connection cable solid wire
Connection cable stranded wire
Current consumption (X32.9,
X32.1)
Voltage load capacity
Fig.5-17:
Technical Properties
View
Fig.5-18:
View
Observe the functional differences between the connection points
X33 and X40, depending on the supply unit:
Supply units with integrated mains contactor:
X33 provides message signals on the status of the integra‐
ted mains contactor
Supply units without integrated mains contactor:
X40 receives message signals on the status of the external
mains contactor
The connection point X40 is available at supply units HMV01.1R-
W0120 with hardware index ≥ A11 (see type plate). These supply
units do not have connection point X33.
Bosch Rexroth AG
Instructions for Use
Unit
Min.
Typ.
9
Spring terminal
Pins on device
0,5
mm
2
0,5
mm
2
AWG
20
A
0,1
V
45/81
Max.
1,5
1,5
16
DC30