4.3

TECHNICAL DATA.

Nominal heat input
DHW minimum heat input
CH minimum heat input
Nominal heat output (useful)
DHW minimum heat output (useful)
CH minimum heat output (useful)
(*) Effective thermal efficiency 80/60 Nom./Min.
(*) Efficiency at 30% nominal heat output load
Heat loss at case with burner Off/On
Heat loss at flue with burner Off/On
Central heating circuit max. operating pressure
Central heating circuit max. operating temperature
Adjustable central heating temperature
System expansion vessel total volume
Expansion vessel factory-set pressure
Water content in generator
Total head available with 1000 l/h flow rate
Domestic hot water adjustable temperature
Nominal domestic hot water circuit flow limiter
Min. pressure (dynamic) domestic hot water circuit
Domestic hot water circuit max. working pressure
Minimum D.H.W. flow rate
Specific flow rate (∆T 30°C)
Drawing capacity in continuous duty (∆T 30°C)
Weight of full boiler
Weight of empty boiler
Electrical connection
Power input
Installed electric power
Equipment electrical system protection
Ambient operating temperature range
Maximum flue overheating temperature
NO
class
X
Weighted NO
X
Weighted CO
Type of appliance
Category
- Fume temperature values refer to an air inlet temperature of
15°C.
- The data relevant to domestic hot water performance refers to a
dynamic inlet pressure of 2 bar and an inlet temperature of 15°C;
the values are measured directly at the boiler outlet considering
that to obtain the data declared mixing with cold water is nec-
essary.
48
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
kW (kcal/h)
%
%
W
W
bar
°C
°C
l
bar
l
kPa
°C
l/min
bar
bar
l/min
l/min
l/min
kg
kg
V/Hz
A
W
-
°C
°C
-
mg/kWh
mg/kWh
C12 /C32 / C42 / C52 / C62 / C82 / B22p / B52p
- The max. sound level emitted during boiler operation is < 55dBA.
The sound level value is referred to semianechoic chamber tests
with boiler operating at max. heat output, with extension of flue
gas exhaust system according to product standards.
- * Efficiencies refer to the net calorific value.
- The weighted NOx value refer to the net calorific value.
29.7 (25536)
9.9 (8480)
12.7 (10902)
27.6 (23731)
8.6 (7394)
11.0 (9458)
92.9/86.8
89.3
129/125
12/1834
3
90
35 - 85
7.4
1
2.8
31.0
30 - 60
10
0.3
10
1.5
13.2
-
40.8
38.0
230/50
0.74
130
IPX5D
0 ÷ 40
180
3
150
109
II2H3P