• Vertical kit with aluminium tile Ø 80/125.
Kit assembly (Fig. 21): install the concentric flange (2) on the
central hole of the boiler inserting the gasket (1) and tighten
using the screws in the kit. Fit the male end (smooth) of the
adapter (3) into the female end of the concentric flange (2).
Imitation aluminium tile installation. Replace the tile with the
aluminium sheet (5), shaping it to ensure that rainwater runs
off. Position the fixed half-shell (7) on the aluminium tile and
insert the intake-exhaust pipe (6). Fit the Ø 80/125 concentric
terminal pipe with the male end (6) (smooth) to the female end
of the adapter (3) (with lip gasket) up to the stop; making sure
that the wall sealing plate has been fitted, this will ensure sealing
and joining of the elements making up the kit.
• Coupling extension pipes and concentric elbows. To install
push-fitting extensions with other elements of the flue extraction
elements assembly, proceed as follows: engage the concentric
pipe or elbow with the male side (smooth) on the female section
(with lip seal) up to the stop on the previously installed element.
This will ensure sealing and joining of the elements correctly.
ATTENTION:
if the exhaust terminal and/or exten-
sion concentric pipe needs shortening,
consider that the internal pipe must always
protrude by 5 mm with respect to the external
pipe.
8
7
5
4
6
3
2
1
The kit includes:
N°1 - Gasket (1)
N°1 - Female concentric flange (2)
N°1 - Adapter Ø 60/100 for
Ø 80/125 (3)
N°1 - Wall sealing plate (4)
N°1 - Aluminium tile (5)
N°1 - Concentric intake-exhaust
terminal Ø 80/125 (6)
N°1 - Fixed half-shell (7)
N°1 - Mobile half-shell (8)
This specific terminal enables flue exhaust and air intake, necessary
for combustion, in a vertical direction.
N.B.: The Ø 80/125 vertical kit with aluminium tile enables instal-
lation on terraces and roofs with a maximum slope of 45% (25°)
and the height between the terminal cap and half-shell (374 mm)
must always be respected.
The vertical kit with this configuration can be extended up to a
maximum of 12,200 mm vertical rectilinear, with the terminal
included (Fig. 22). This configuration corresponds to a resistance
factor of 100. In this case the special extensions must be requested.
The terminal Ø 60/100 can also be used for vertical exhaust, in
conjunction with concentric flange code 3.011141 (sold separate-
ly). The height between the terminal cap and half-shell (374 mm)
must always be respected.
The vertical kit with this configuration can be extended up to
a maximum of 4,700 mm vertical rectilinear, with the terminal
included (Fig. 22).
C
32
21
C
32
22
21