MAINTENANCE

The unit must be turned OFF and disconnected from the power source whenever
performing service, maintenance functions or cleaning the refrigerated area.
DANGER
Refrigerators and Freezers
The interior and exterior can be cleaned using soap and warm water. If this isn't sufficient, try ammonia and
water or a nonabrasive liquid cleaner. When cleaning the exterior, always rub with the "grain" of the stainless
steel to avoid marring the finish.
Do not use an abrasive cleaner because it will scratch the stainless steel and plastic and can damage the
breaker strips and gaskets.
Cleaning the Condenser Coil
The condenser coil requires regular cleaning, and is recommended every 90 days. In some instances, you
may find that there is a large amount of debris and dust or grease accumulated prior to the 90 day time
frame. In these cases the condenser coil should be cleaned every 30 days.
If the build up on the coil consists of only light dust and debris, the condenser coil can be cleaned with a
simple brush. Heavier dust build-up may require a vacuum or even compressed air to blow through the
condenser coil.
If heavy grease is present, there are de-greasing agents available for refrigeration use and specifically for
the condenser coils. The condenser coil may require cleaning with the de-greasing agent and then blown
through with compressed air.
Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times.
Continuous operation with dirty or clogged condenser coils can result in compressor failures. Neglecting the
condenser coil cleaning procedures will void any warranties associated with the compressor or cost to
replace the compressor.
Never use a high pressure water wash for this cleaning procedure as water can damage
the electrical components located near or at the condenser coil.
DANGER
In order to maintain proper refrigeration performance, the condenser fins must be cleaned of dust, dirt and
grease regularly. It is recommended that this be done at least every three months. If conditions are such that
the condenser is totally blocked in three months, the frequency of cleaning should be increased. Clean the
condenser with a vacuum cleaner or stiff brush. If extremely dirty, a commercial-grade condenser cleaner
may be required.
Stainless Steel Care and Cleaning
To prevent discoloration of rust on stainless steel, several important steps need to be taken. First, we need
to understand the properties of stainless steel. Stainless steel contains 70-80% iron which will rust. It also
contains 12-30% chromium which forms an invisible passive film over the steels surface which acts as a
shield against corrosion. As long as the protective layer is intact, the metal is still stainless. If the film is
broken or contaminated, outside elements can begin to breakdown the steel and begin to form rust of
discoloration. Proper cleaning of stainless steel requires soft cloths or plastic scouring pads.
NEVER USE STEEL PADS, WIRE BRUSHES OR SCRAPERS!
DANGER