Download Print this page

Operation - Kelvinator KCHUC23F Service, Installation And Care Manual

Upright chiller & freezer

Advertisement

Service and Installation Manual

OPERATION

Do not throw items into the storage area. Failure to heed these recommendations
could result in damage to the interior of the cabinet.
CAUTION
Refrigerated cycle
Refrigerators: During the refrigeration cycle, the evaporator fans wilt run continuously even when one or
more doors are open. The door switch will activate the lights when opened.
Every 6 hours, the unit will turn off and to allow the evaporator coil to defrost. The controller now
1.
displays the defrost symbol. When the coil temperature reaches 41°F or after 20 minutes of defrost, the
unit will turn on again.
Anti-condensation heaters on door frames work in conjunction with the compressor.
2.
The factory setting for the temperature range is 34° to 38° F.
3.
Freezers: During the refrigeration cycle the controller supplies power to the condensing unit and evaporator
fan motors. The evaporator fans will run at any time when the evaporator coil temperature is below 54°F,
they will also keep running during when door is open but cycle off during a defrost period. The door switch
will activate the lights when opened.
Every 6 hours, the unit will turn off and electric heater will turn on to start the defrost cycle. The
1.
controller now displays the defrost symbol. When the coil temperature reaches 45°F or after 20 minutes
of defrost, the unit will turn on again.
Anti-condensation heaters on door frames work in conjunction with the compressor.
2.
The factory setting for temperature range is -7 to -3°F
3.
SOLID-STATE THERMOSTAT DESCRIPTIONS
1. FRONT PANEL COMMANDS
To display target set point; in programming mode it selects a parameter or confirms an
operation.
To start a manual defrost
To view the latest alarm occurrence; in programming mode it browses the parameter
codes or increases the display value
To view the latest alarm occurrence; in programming mode it browses the parameter
codes or decreases the display value
KEY COMBINATION
To lock & unlock the keyboard
To enter in programming mode
To return to the room temperature display
7