Setting Functions And Options - Honeywell Home Smart RTH6585R1006 User Manual

Programmable thermostat
Table of Contents

Advertisement

Available languages

Available languages

Setting functions and options

You can change options for a number of system functions. Available functions depend
on the type of system you have. The functions, along with available options, are
described on pages 18–19.
This thermostat is pre-set for a single-stage heating/cooling system. Setting function
1 for a heat pump will adjust the default settings.
1 Press Fan and s simultaneously and hold
for approximately 3 seconds. The screen
will change to display two numbers and
the button designations will be Done, Back,
blank, Next.
2 Press Next until you see the function
number—the larger number on the left—
you want to set.
3 Change options for any function by
pressing s or t until the correct option
(smaller number on right) is displayed.
4 Repeat Steps 2 and 3 until you have set all
functions that you wish to change.
5 When you have made all changes, press
Done to save and exit.
System setup
Function
1
Select System
Type
If you are not sure
of your heating/
cooling system
type or have other
questions, go to
honeywellhome.
com/support
2
Heat Pump
Changeover Valve
(for heat pumps
only)
3
Heating Fan
Control
69-2715EF—07
Settings & Options
0
Heat/cool: Gas, oil or electric heating with central air conditioning.
1
Heat pump: Heat pump without backup or auxiliary heat.
Heat only: Gas, oil or hot water heat without central air conditioning.
2
3
Heat only with fan: Gas, oil or electric heat without central air
conditioning.
4
Cool only: Central air conditioning only.
5
Heat pump: Heat pump with backup or auxiliary heating.
6
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2
cooling stages (wires on Y and Y2).
7
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1
cooling stage (wire on Y).
8
Heat/Cool Multiple stages: 1 heat stage (wires on W), 2 cooling
stages (wire on Y and Y2).
0
Cooling changeover valve: Use this setting if you connected a wire
labeled "O" to the O/B terminal.
1
Heating changeover valve: Use this setting if you connected a wire
labeled "B" to the O/B terminal.
0
Gas or oil heat: Use this setting if you have a gas or oil heating system
(system controls fan operation).
1
Electric heat: Use this setting if you have an electric heating system
(thermostat controls fan operation).
18
HOLD
MCR33883
HOLD
MCR33884

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Smart rth6580wf1001Smart rth6500wf series