WARNING ‒ Risk of burns!
Objects left on the hob may tip over when the
filter cover is opened. This may cause burns.
▶ Clear the hob before opening the filter
cover.
WARNING ‒ Risk of injury!
The filter cover may swing out.
▶ Open the filter cover slowly.
▶ Take hold of the filter cover after opening
until it no longer swings out.
▶ Close the filter cover slowly.
Risk of injury when opening and closing the
hinges.
▶ Keep your hands away from the hinges.
WARNING ‒ Risk of electric shock!
Sharp-edged components inside the appli-
ance may damage the connecting cable.
▶ Do not kink or trap the connecting cable.
If the appliance or the power cord is dam-
aged, this is dangerous.
▶ Never operate a damaged appliance.
▶ Never pull on the power cord to unplug the
appliance. Always unplug the appliance at
the mains.
▶ If the appliance or the power cord is dam-
aged, immediately unplug the power cord
or switch off the fuse in the fuse box.
▶ Call customer services. → Page 34
Improper repairs are dangerous.
▶ Repairs to the appliance should only be
carried out by trained specialist staff.
▶ Only use genuine spare parts when repair-
ing the appliance.
▶ If the power cord of this appliance is dam-
aged, it must be replaced by trained spe-
cialist staff.
Incorrect installation is dangerous.
▶ Connect and operate the appliance only in
accordance with the specifications on the
rating plate.
▶ Connect the appliance to a power supply
with alternating current only via a properly
installed socket with earthing.
▶ The protective conductor system of the do-
mestic electrical installation must be prop-
erly installed.
▶ Never equip the appliance with an external
switching device, e.g. a timer or remote
control.
▶ When the appliance is installed, the mains
plug of the power cord must be freely ac-
cessible. If free access is not possible, an
all-pole isolating switch must be installed in
the permanent electrical installation accord-
ing to the conditions of Overvoltage Cat-
egory III and according to the installation
regulations.
▶ When installing the appliance, check that
the power cable is not trapped or dam-
aged.
ATTENTION!
There is a risk of damage to the appliance if
the cable is coiled up.
▶ Always secure the cable firmly using the
strain relief so that it does not coil up fully
in the appliance.
16.5 General information
Follow these general instructions during the installation.
¡ For the installation, observe the currently valid build-
ing regulations and the regulations of the local elec-
tricity and gas suppliers.
¡ When discharging the exhaust air, the official and
legal regulations, such as the regional building
code., must be observed.
¡ In order to freely access the appliance for servicing,
select an easy-to-reach installation site.
¡ The surfaces of the appliance are sensitive. Avoid
damaging them during installation.
16.6 Instructions for the electrical
connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
WARNING ‒ Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
The mains plug for the mains power cable must be
easily accessible after the appliance is installed.
If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.
The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.
Sharp-edged components inside the appliance may
damage the connecting cable.
Do not kink or trap the connecting cable.
¡ The connection data can be found on the rating
plate. → Page 34
¡ The connecting cable is approx. 1.30 m long.
¡ This appliance complies with the EC interference
suppression regulations.
¡ The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.