TYPICAL LAYOUTS
DS5100-x4xx models can only be integrated into EBC networks as slave scanners where
SC5000 is the Master Controller. To do this:
1. Physically mount and electrically connect the DS5100 scanner in the application.
2. To set the DS5100 scanner as an EBC Slave, follow the
procedure described in step 4, X-PRESS Configuration.
3. Run Discovery from the SC5000 System Info page to discover all scanners in the
network.
NOTE: The DS5100 scanners can also be added to the EBC network using
the Add button in the SC5000 GUI.
5
EBC network selection
79