EBC/Profinet-IO Network Selection (only on Profinet-IO dual port models)
For on-board Profinet 2 port models, the DS5100 scanner can be configured to work as a
Slave in an EBC network. The only way to make this selection is through the X-PRESS
button.
1. Enter the EBC/Profinet-IO Network Selection function by holding the X-PRESS push button
pressed until the all X-PRESS LEDs are off.
2. Release the button to enter the Network Selection function.
Once entered, the scanner automatically performs the procedure to set itself as either an
EBC slave or a Profinet-IO slave depending on the previous state of the network
selection.
Figure 10 – X-PRESS Interface: EBC/Profinet-IO Network
Selection Function
The scanner will restart at the end of the process.
NOTE: To reset the scanner to its default Profinet interface settings, you can
also perform the Reset Scanner to Factory Default procedure as described in
the paragraph below.
Reset Scanner to Factory Default (Optional)
If it ever becomes necessary to reset the scanner to the factory default values, you can
perform this procedure by holding the X-PRESS push button pressed while powering up the
scanner and waiting for all the X-PRESS LEDs to blink simultaneously three times before
releasing the push button.
This procedure takes ≈ 5-6 seconds for Serial Models, ≈ 10 seconds for Ethernet Models, ≈
20 seconds for 2 port Profinet-IO models. At the end of the procedure the Configuration and
Environmental parameters are reset and the message "Default Set" is shown on the scanner
display. If connected through a CBX500 with BM150 display module, the "Default Set"
message is also shown on the CBX500 display.
10
DS5100 REFERENCE MANUAL
The procedure is as follows:
A) enter the Network selection function.
B) wait until the "EBC Slave" o
"Profinet-IO" message appears on
the display (indicating the scanner
has been set and saved.