NOTE: The auxiliary serial interface of the slave scanners can be used in
Local Echo communication mode to control any single scanner (visualize
collected data) or to configure it using the Genius utility or the Genius based
Host Mode programming procedure.
The ID-NET termination resistor switches must be set to ON only in the first and
last CBX connection box.
CBL-1480-xx
Master
Power
CAB-PW-EXT
3
CBX500 w BM200
CAB-AUX03
QL500
ID-NET
CBL-1480-xx
CAB-PW-EXT
Ethernet Interface
84
PS
1 4
Ethernet
5
Figure 61 – ID-NET Synchronized Layout
DS5100 Master with CBX500 + DS5100 Slaves with QL100
Power
Master
PS
Figure 62 – ID-NET Synchronized Layout
DS5100 Master with QL500 + DS5100 Slaves with QL100
DS5100 REFERENCE MANUAL
QL100
ID-NET Slave Nodes
CBL-1480-xx
The ID-NET network must be terminated through
the internal switch of the CBX500 and inserting
an ID-NET terminator into the last QL in the
network.
Host
 BA600 ID-NET™ Out
 BA400 Ext. Power
 BA500 Trigger
 BA300 Service
QL100
CBL-1480-xx
Slave Nodes
The ID-NET network must be terminated inserting
an ID-NET terminator into the last QL in the
network.
ID-NET on the QL500 is internally terminated.
Host
QL100
CBL-1490
ID-NET
Terminator
QL100
CBL-1490
ID-NET