7.4. Emptying the dust collecting tank
The dust collection container must be cleaned after a certain number of operating hours. This range
depends on the amount of dust. The dust collecting tank may only be filled up to a maximum of 25%.
The filling level has to be proofed at least once a week.
CAUTION
Whirling up dust is possible due to the polluted filter cartridges! Danger of
unintentional automatic cleaning with the unit switched off.
The filter cartridges must be cleaned before emptying the dust collecting tank.This is done
by carrying out 3 manual cleanings via the unit control (see separate operating
instructions).The filter unit must be switched off beforehand but without disconnecting the
unit from the power supply.After the cleaning, disconnect the filter unit from the power supply
and secure it against being switched on again.After cleaning the filter cartridges wait about 5
minutes before opening the service door.
Before emptying the dust collecting tank hold ready an appropriate container (e.g. PE bag). The
bags are optionally available at TEKA, see list of spare parts. We recommend having PE bags in
stock.
●
Open the service door of the dust collecting housing (see chapter 2.1).
●
Open the toggle levers (B) of the dust collecting tank (A).
Risk of contusion when opening the toggle levers.
●
Carefully pull the dust collecting tank out of the housing.
●
Remove the slip-on frame (C) from the dust collecting tank.
●
Close the dust collection bag (e.g. with a cable fastener).
●
Remove the dust collection bag and store or dispose of it according to the regulations.