Dust at the dust
collecting tank.
Dust at the service door
of the filter housing.
Suction power too low
(smoke hardly
extracted).
The system is very noisy. The motor rotates in the wrong
BA_FilterCube_4_IFA_20230808_EN
There is too much dust in the dust
collection container.
The toggle closures are not closed.
The seal of the dust collecting tank is
damaged.
The compressed air for the dedusting
is set too high.
The door is not correctly closed.
The seal between the service door and
filter housing is damaged.
The compressed air for the dedusting
is set too high.
Escape of dust at the hinge.
Filter element is saturated.
Filter elements are saturated because
no compressed air is connected.
Damage at the extraction elements.
The motor rotates in the wrong
direction.
Suction line contracted.
Exhaust line contracted.
Maybe throttle valves are used in the
suction line.
direction.
There is no silencer mounted.
The suction line or exhaust line are not
mounted.
The unit is untight.
Empty the dust collecting tank.
Close the toggle closers.
The seal must be replaced.
Reduce the compressed air.
Close the door.
The seal must be replaced.
Reduce the compressed air.
The hinge must be reoriented or
replaced.
Replace the filter package,
dispose of old filter properly!
Connect compressed air.
Replace the extraction elements.
The rotating field of mains
connection point must be
changed.
Check and fix.
Check and fix.
Adjust throttle valves.
The rotating field of mains
connection point must be
changed.
Mount the silencer.
Mount the line.
Check and fix.
29