14.2. General maintenance

The described maintenances are independent from the demands of the system operations.
The operator is obliged to carry out repeated inspections and functional tests according to national
regulations. If not otherwise covered by national regulations, the described maintenance intervals must
be respected.

Visual inspection of the device

14.2.1. Visual inspection of the device
Visual inspection: Observation that there are no visible safety-related defects.
WARNING
Danger arising from the ready to operate condition of the device.
Follow the procedure as described in the chapter "Set to maintenance state".
The following steps must be carried out in the course of the visual inspection:
Check if all required pipeline elements, cable connections and hoses are connected to the filter
unit
Check all electrical earthing connections and cables for visible damages.
Ensure that all parts are firmly connected.
Check all connection points of the filter unit for escaping dust.
Check all metal parts for corrosion or damages / changes of the coating.
Check the inner filter area and the filter housing.
Visual inspection of the control and operating elements as well as the outside running cables for
damages.
Check the dust collecting tank for tightness, check the sealing rubber of the tank.
BA_FilterCube_4_IFA_20230808_EN
Chapter Maintenance interval
14.2.1
14.2.2
14.2.3
14.2.4
14.2.5
14.2.6
35
weekly
monthly
monthly
monthly
annually
annually