Connecting Power
3 PHASE SINGLE VOLTAGE
WITH THERMAL PROTECTOR
}
P1
THERMOSTAT
P2
LEADS
T1
L1
T2
L2
T3
L3
T1
THERMAL
1
PROTECTOR
3
6
T3
NOTE: TO REVERSE ROTATION, INTERCHANGE ANY TWO LINE LEADS (L1, L2, or L3)
Fig. 3
Electric Agitators
Refer to the motor wiring diagram (Fig. 3).
The required power supply varies depending on your
model number. For power supply requirements, see
Technical Data on page 27 of this manual.
WARNING
ELECTROCUTION HAZARD
Make sure that your installation complies
with National, State, and Local codes for
the installation of electrical equipment.
Have only a qualified electrician make the connec-
tions.
1. Verify the electrical supply and control equipment
are properly rated for the motor being used.
6
310500
Installation
P1
P2
THERMAL
PROTECTOR
4
2
5
T2
CONNECT LEADS P1 AND P2 IN SERIES WITH THE HOLDING
COIL OF THE MOTOR CONTROLLER WHICH USES A MANUAL
MOMENTARY START SWITCH.
MOTOR WIRING
3 PHASE DUAL VOLTAGE
WITH THERMAL PROTECTOR
}
THERMOSTAT
T1
LEADS
T4
T7
1
4
3
2
6
5
T9
T6
T3
2. Check the stator winding insulation resistance. If
the resistance is less than 1 megohm, call Graco
Customer Service for assistance.
3. With power disconnected, connect all the electrical
leads as indicated in the wiring diagram.
ELECTROCUTION HAZARD
Contact with electricity can be fatal! To
reduce risk of serious injury or death,
make sure the power supply lines to the
agitator are disconnected from the power supply
when servicing and repairing the equipment.
NOTE: The blade rotation should be clockwise, look-
ing down from the motor to the blade. To change the
direction of rotation, disconnect power from the agita-
tor power supply lines, and change the leads as indi-
cated in Fig. 3.
LOW
VOLTAGE
T1
T1
L1
T2
T7
T3
T2
L2
T4
T8
T7
T3
L3
T5
T9
T8
T4
T6
T5
T9
T6
T8
T5
T2
WARNING
HIGH
VOLTAGE
L1
L2
L3