Robert Juliat ARTHUR Manual

Led followspots
Hide thumbs Also See for ARTHUR:
Table of Contents

Advertisement

Quick Links

LED FOLLOWSPOTS
1014TC / 1014TCLT
Angles
Controls
Standard / CE
5.5° – 15°
On the side
5.5° – 15°
On top
V1
- FIRMWARE: V2.07
VALIDATION : 18/09/23
DN41195800-B
Robert Juliat S.A.S. 32, rue de Beaumont, F 60530 Fresnoy-en-Thelle - phone : +33 (0)3 44 26 51 89 - info@robertjuliat.fr
(TOP CONTROL)
800 W FOLLOWSPOTS
Model
North American
1014
1014C
1014TC
1014CTC
www.robertjuliat.com
1014 / 1014LT
Angles
Controls
Standard / CE
4° – 10°
On the side
1014LT
4° – 10°
On top
1014TCLT
Model
North American
1014CLT
1014CTCLT

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARTHUR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Robert Juliat ARTHUR

  • Page 1 On top 1014TC 1014CTC 4° – 10° On top 1014TCLT 1014CTCLT - FIRMWARE: V2.07 VALIDATION : 18/09/23 DN41195800-B Robert Juliat S.A.S. 32, rue de Beaumont, F 60530 Fresnoy-en-Thelle - phone : +33 (0)3 44 26 51 89 - info@robertjuliat.fr www.robertjuliat.com...
  • Page 2: Table Of Contents

    4.9 Frost and correction filters ..................22 4.9.1 Range..........................22 4.9.2 Control ......................... 22 Robert Juliat reserve the right to change or alter any of the items detailed on this page, to increase or improve manufacturing techniques without prior notice.
  • Page 3: User's Instructions

    1 User’s instructions GENERAL INSTRUCTIONS Not for residential use. These fixtures must only be serviced by a qualified technician. In addition to the instructions indicated on this page, relevant health and safety requirements of the appropriate EU Directives must be adhered to at all times. This fixture is in compliance with section 17 - Lighting appliance for theatre stages, television, cinema and photograph studios.
  • Page 4: Presentation

    2 Presentation 2.1 Functions 4* 5* Functions Yoke 12 Local display Tilt locking handle 13 Keypad Side operating handle 14 Identification plate Iris control (1014/1014LT only) 15 Data connectors (OUT and IN) 4* Iris control (1014TC/1014TCLT only) 16 Power connectors (IN and OUT) Dimming control (1014/1014LT only) 17 Power switch (thermal breaker) 5* Dimming control (1014TC/1014TCLT only)
  • Page 5: Identification Label

    2.2 Identification label Description 18 15 16 1. MOD. : Model 2. VERS. : Version 3. U : Nominal voltage input (V) 4. I : Nominal intensity (A) 5. P : Maximum power input (W) 6. IP : International Protection Rating 7.
  • Page 6: Accessories

    2.4 Accessories Reference Description Monopod stand for overhead followspot GT4000 Tripod stand with safety chain - SWL: 130 Kg - max. height: 1030 mm GT4000S Tripod stand without safety chain - SWL: 130 Kg - max. height: 1030 mm GT4000R Tripod stand with ball head rotation with security chain - SWL: 130 Kg - max.
  • Page 7: Set-Up

    3 Set-up 3.1 Mechanics 3.1.1 Operating positions 3.1.2 Minimum distance between a flammable material and the lighting unit 1.3 m / 4.3 ft 1014 & 1014TC 0.8 m / 2,6 ft 1014LT & 1014TCLT 5°C 40°C 3.1.3 Instructions for use Minimum : Maximum : 40°F...
  • Page 8: Yoke Adjustment

    Place one of the stand legs towards the front to support the maximum tilt position. 3.1.7 Stand set-up The unit must be installed only on a Robert Juliat compatible stand / head : Monopod stand for overhead followspot GT4000 Tripod stand with safety chain - SWL: 130 Kg - max. height: 1030 mm GT4000S Tripod stand without safety chain - SWL: 130 Kg - max.
  • Page 9: Electrical Information

    3.2 Electrical information 3.2.1 LED source Never touch or scratch the LED surface. Cf. 6.1.4 LED cleaning procedure if cleaning is necessary. 3.2.2 Power supply Power supply Voltage Frequency Input power Connectors Neutrik powerCON TRUE1 TOP 4,3 A / 960 W @ 230V 100 T 240 V 50-60 Hz 8,7 A / 1030 W @ 120V...
  • Page 10: Data

    Power ON 3.3 DATA 3.3.1 DMX 512-A / RDM Protocol Input connector Output connector USITT DMX 512-A XLR 5-pin XLR 5-pin DATA connectors PIN # Description Shielding Foil & Braided Shield DMX (-) conductor of 1 twisted pair DMX (+) conductor of 1 twisted pair Not used...
  • Page 11: Art-Net / Sacn

    3.3.2 Art-Net / sACN • With external switch Protocol Input connector Output connector Art-Net RJ45 #1 or #2 sACN Daisy chain: Art-Net sACN Network switch* (*) A 1000 base-T switch that supports IGMP (Internet Group Management Protocol) is necessary if the unit is connected to a network switch to control multiple devices.
  • Page 12: Accessories

    3.4 Accessories 3.4.1 Full closing iris cassette (1014 & 1014LT) (1014TC & 1014TCLT) 3.4.2 Colour changer unit - boomerang Dimensions Cf. 4.8.1 EN - 10 -...
  • Page 13: Colour Changer Unit - Push-Pull (Option)

    3.4.3 Colour changer unit - push-pull (option) Dimensions Cf. 4.8.1 3.4.4 Gobo holder 'A' size gobo Dimensions Cf. 4.7.1 'B' size gobo (LT version) Dimensions Cf. 4.7.1 EN - 11 -...
  • Page 14: Frosted / Correction Filter (Option)

    3.4.5 Frosted / Correction filter (option) Dimensions Cf. 4.9.1 3.4.6 Internal glass holder 120 x 120 mm (option) EN - 12 -...
  • Page 15: Stands (Option)

    3.4.7 Stands (option) • GT4000 Series : Please refer to the relevant stand technical files for further details. Stand set-up, refer to Cf. 3.1.7 3.4.8 Telrad followspot sight (option) Followspot sight guide available @ www.robertjuliat.com/followspots/ Accessories Caution: - Do not install the followspot sight on the lamp house to avoid blocking the ventilation vents. - Secure the sight with a suitable safety cable.
  • Page 16: Flight-Case (Option)

    3.4.10 Flight-case (option) GT4000 stand compartment Inner side view Accessories GT4000 stand compartment compartment Inner overhead view EN - 14 -...
  • Page 17: Operations

    4 Operations 4.1 Light intensity 4.1.1 Range 100% 4.1.2 Control Remotely with DMX512-A protocol Locally via dimming control handle Locally via Standalone mode Art-Net / sACN (1014 & 1014LT) DMX512-A T selection in DATA MODE / PROTOCOL / STANDALONE (1014TC & 1014TCLT) HTP mode (Highest Takes Precedence): Light output is the highest value of DMX512 command or local control 4.1.3 Parameters...
  • Page 18: Master Control

    4.1.3.3 Master control T DMX Mode 5 / 6 In order to supervise the operator from the console, master control DMX channel can be used. This channel limits the maximum value of the dimmer shutter. By using this function, it is possible to obtain synchronised fades with several spots or to give intensity limits (minimum and maximum) to the operator .
  • Page 19: Strobe

    4.2 Strobe 4.2.1 Range Strobe duration 255 = 20ms 0 = OFF 1 = 1ms Strobe speed 0 = 0.1Hz 255 = 10Hz 4.2.2 Control DMX512-A Remotely with DMX512-A / Art-Net / sACN protocols Mode 3 – 4 – 5 – 6 4.3 Response time 4.3.1 Range X ms...
  • Page 20: Beam Size Adjustment

    4.4 Beam size adjustment 4.4.1 Range Beam angle Field angle Model Angles Minimum angle Maximum angle Beam angle 5.4° 13.2° ARTHUR 1014 & 1014TC Field angle 5.8° 13.6° Beam angle 4.1° 10° ARTHUR 1014LT & 1014TCLT Field angle 4.5° 10.6°...
  • Page 21: Pan / Tilt

    4.5 Pan / Tilt 4.5.1 Range Function Range 0 T 360° TILT Yoke position #1 Yoke 61° position #5 30° with tilt stopper 44° without tilt stopper 4.5.2 Control Unlock Lock EN - 19 -...
  • Page 22: Iris

    4.6 Iris 4.6.1 Range • Irising 100% Closed iris 4.6.2 Control (1014 & 1014LT) (1014TC & 1014TCLT) 4.7 Gobo 4.7.1 Range Type Standard gobo - A size Standard gobo - B size (for LT version) Ø100 mm Ø86 mm Ø72 mm •...
  • Page 23: Colour

    4.8 Colour 4.8.1 Range Type Coloured gel filter Ø270 mm Dimension Cf. section: 3.4.2 & section 3.4.3 Installation Place dark colours towards the front end. 4.8.2 Control Unlock = release colours Colour engaged Push / Pull EN - 21 -...
  • Page 24: Frost And Correction Filters

    4.9 Frost and correction filters 4.9.1 Range Type Frost or Correction filter Ø120 mm Dimension Installation Cf. section: 3.4.6 4.9.2 Control Frost glass Spare filter EN - 22 -...
  • Page 25: Controls And Parameters

    5 Controls and parameters 5.1 Local display and controls 5.1.1 Display Function Exit the current menu option and/or go back Enter the current menu option and/or valid Scroll through menus and/or Increase data value Scroll through menus and/or Decrease data value Scroll through menus and/or Increase data value Scroll through menus and/or Decrease data value 5.1.2 Home screen...
  • Page 26: Menu

    5.1.3 Menu DATA FACTORY STATUS SETUP MODE DEFAULT Reset to factory settings. PROTOCOL DISPLAY SELFTEST • DMX • INTENSITY • RDM • AUTO OFF • WDMX • ARTNET • SACN • STANDALONE SYSTEM ID • SERIAL NUMBER DATA SETUP • SOFTWARE VERSION PERSONALITY •...
  • Page 27: Parameters

    5.1.4 Parameters 5.1.4.1 Intensity T Selection in SETUP / DISPLAY / INTENSITY menu Display Mode Description SETUP DISPLAY INTENSITY Adjust the intensity of the screen Intensity : 6 Intensity press OK To change value, press buttons : to validate Intensity Auto OFF 5.1.4.2 Auto-OFF T Selection in SETUP / DISPLAY / AUTO OFF menu...
  • Page 28: Dmx512 - A Remote Control

    5.2 DMX512 - A remote control 5.2.1 Protocol E1.11 – 2008, USITT DMX512-A 5.2.2 Configuration DATA MODE Data Mode Protocol Press OK DATA MODE Press OK PROTOCOL STATUS SETUP FAC PERSONALITY DMX ADDI to enter to validate DATA MODE Caution: Activate DMX in protocol mode beforehand.
  • Page 29: Dmx Chart

    5.2.4 DMX chart Mode 1: Mode 2: Mode 3: Mode 4: Mode 5: Mode 6: DMX Channel Dimmer8B Dimmer16B Profile8B Profile16b Followspot8b Followspot16b Dimmer Dimmer Dimmer Dimmer Dimmer Dimmer Dimmer fine Strobe duration Dimmer fine Master Dimmer fine Strobe speed Strobe duration Strobe duration Master...
  • Page 30: Rdm Remote Control

    5.3 RDM remote control 5.3.1 Protocol ANSI E1.20 – 2010 / ANSI E1.37 - 1 / ANSI E1.37 - 2 For more information about RDM protocol: http://www.rdmprotocol.org/ ARTHUR 800W LED FOLLOWSPOT Function description V2.07 Queued Message Network Management DISCOVERY_UNIQUE_BRANCH DISCOVERY_MUTE...
  • Page 31 ARTHUR 800W LED FOLLOWSPOT Function description V2.07 Queued Message Control IDENTIFY_DEVICE RESET_DEVICE PERFORM_SELFTEST SELF_TEST_DESCRIPTION RDMnet Management LIST_INTERFACES INTERFACE_LABEL INTERFACE_HARDWARE_ADRESS_TYPE1 IPV4_DHCP_MODE IPV4_CURRENT_ADDRESS IPV4_STATIC_ADDRESS INTERFACE_RELEASE_DHCP INTERFACE_APPLY_CONFIGURATION IPV4_DEFAULT_ROUTE DNS_IPV4_NAME_SERVER DNS_HOSTNAME PID Manufacturer SELFTEST_RESULT CURRENT_IP_ADDRESS CURRENT_NETMASK CURRENT_DRIVER_STATUS CUSTOM_RESPONSE_TIME_DESCRIPTION CUSTOM_RESPONSE_TIME_VALUE DATA_MODE_DESCRIPTION DATA_MODE_VALUE STANDALONE_VALUE_DESCRIPTION STANDALONE_VALUE SACN_UNIVERSE_VALUE_DESCRIPTION...
  • Page 32: Art-Net Remote Control

    5.4 Art-Net remote control Artistic Licence Art-Net v3. 5.4.1 Protocol For more information about Art-Net protocol: http://art-net.org.uk/ (*) Caution: 5.4.2 Configuration Activate Art-Net in protocol mode beforehand. DATA MODE Data Mode Protocol Press OK DATA MODE Press OK Press OK STATUS SETUP PROTOCOL...
  • Page 33: Sacn Remote Control

    5.5 sACN remote control 5.5.1 Protocol ANSI E1.31 – 2009 sACN (Streaming-ACN) 5.5.2 Configuration (*) Caution: Activate sACN in protocol mode beforehand. DATA MODE Data Mode Protocol Press OK DATA MODE STATUS SETUP Press OK PROTOCOL PERSONALITY DMX ADDI Press OK to enter to validate to validate...
  • Page 34: Fan Cooling Modes

    5.6 Fan cooling modes 5.6.1 Range Modes Silent Normal Full Cooling < 35 dB(A) < 37 dB(A) < 39 dB(A) Ambiant temperature: 30°C 100% Brightness 5.6.2 Control DMX512-A Remotely by DMX512-A Locally T selection in Mode 3 – 4 – 5 – 6 SETUP / COOLING EN - 32 -...
  • Page 35: Local Potentiometer

    5.7 Local potentiometer T selection in SETUP / LOCAL POTENTIOMETER Function Parameters Description (1014 & 1014LT) Setup Disable SETUP LOCAL POT SETUP LOCAL POT SETUP Setup Enable Disable SETUP ROTATION CALIBRATION Press OK to validate Enable (1014TC & 1014TCLT) Rotation Normal (CW): Clockwise SETUP...
  • Page 36: Web Interface

    (see 6.5 Factory defaults). 5.8.3 Network IP of the computer The computer must be on the same network as the Arthur followspot. Please refer to your computer Operating System to change IPV4 parameters : •...
  • Page 37: Service

    6 Service 6.1 Preventive maintenance 6.1.1 Frequency General maintenance should be performed at least once a year or more frequently if the equipment is operated in adverse conditions (smoke, heat, humidity, touring, etc.). 6.1.2 General cleaning Remove dust from the unit. Front glasses can be cleaned with solutions containing alcohol.
  • Page 38: Led House Cleaning

    6.1.6 LED house cleaning Inner parts & lens holder access. - To clean the optical parts, use a soft cloth in combination with distilled water or isopropyl alcohol recommended for coated optics. Do not use any cleaning product that contains solvents or abrasives, as these can cause surface damage. - Dry with a soft lint-free cloth.
  • Page 39: Analysis

    In case of overheating, light intensity will be reduced by the system. “Power reduction X%” will be shown on the display with the reducing percentage. 6.4 Firmware update 1. Firmware available on www.robertjuliat.com/followspots/Arthur 2. Download and unzip the file There are 4 files: - Firmware (.upd2 format)
  • Page 40: Selftest

    6.6 Selftest Select SELFTEST in the main menu : There are 9 tests available that will be performed by the fixture. STATUS At the end of each test, a PASS/FAIL message will be displayed. SELFTEST Press OK SELFTEST SYSTEM ID LIGHT SOUP to start SELFTEST...
  • Page 41 DMX Test DMX IN DMX data is required to complete this test. DMX IN fail or NO DMX DMX OUT Plug DMX OUT then press OK DMX OUT DMX OUT fail or NO DMX Signal Leds Test LEDS green LEDS blue LEDS Test Report...

This manual is also suitable for:

1014tc1014tclt10141014lt

Table of Contents