6. Remove the rear insulation panel and set it aside.
7. Using a T20
adapter, remove the 4 screws holding
®
the blower motor in place. Push up on the blower motor to
disengage the tabs from range hood cavity back. Remove
the blower motor and set it aside.
A
A. Range hood canopy (inside top)
B. Blower motor
C. Blower motor mounting screws
8. Install the blower motor onto the rear motor mounting
bracket (included with the range hood). Engage the motor
mounting tabs into keyhole slots in rear mounting bracket
and push down to secure. Install the 4 screws removed in
Step 7 and tighten to secure motor bracket.
D
A. Rear motor mounting bracket
B. Motor mounting tabs (2)
10
B
C
A
B
C
C. Blower motor
D. Blower motor mounting screws (4)
9. Install the blower motor assembly into the range hood and
secure with the (4) 4.2 x 8 mm screws.
B
A. Range hood canopy (inside back)
B. 4.2 x 8 mm screws (4)
C. Rear blower motor mounting bracket assembly
10. Reconnect blower motor electrical connector to the
electrical box connector.
11. Reinstall the rear insulating panel.
12. Reinstall the motor cover plate to range hood using the
4 screws removed in Step 3.
13. Reinstall bottom panels assembly to range hood using
the 8 screws removed in Step 2.
14. Attach the 3¹⁄
" x 10" (8.3 cm x 25.4 cm) rectangular vent
4
damper using 3 vent transition mounting screws. Make sure
the vent damper pivot is nearest to the top back edge of the
range hood. See vent connector illustration in "Top Vent
Connector Installation" in this section.
Install Range Hood to Cabinet
1. Remove one of the round knockout from the top or back of
the range hood (depending on your wiring location) for the
wiring strain relief and install a ¹⁄
strain relief.
A. Round knockout
2. Using 2 people, lift range hood into final location. Feed
enough electrical wire through the strain relief to make
connections in the terminal box. Tighten the strain relief
screws.
3. Position the range hood so that the large end of the keyhole
slots are over the mounting screws. Then push the hood
toward the wall so that the screws are in the neck of the
slots. The hood should be against the wall. Tighten the
mounting screws, making sure mounting screws are in the
narrow neck of the slots.
4. Check that damper, if used, rotates up and down freely.
5. Connect ventwork to hood. Seal joints with clamps to make
secure and airtight.
A