Factory Settings
V.n)
The regulator is pre-configured for operation. However, the
user should adjust it to their specific needs. It is possible to
return to the factory settings at any time. When the option
'Factory Settings' is activated, all user settings for the boiler
are lost and replaced by the manufacturer's factory settings.
From this moment, the user's controller parameters may be defined once again.
VI. Servicing Functions for Temperature Regulator ST-81
In order to enter the controller's servicing functions, the user should switch the controller off using
the mains switch, then press the EXIT button and switch the controller on holding the button. The
user should keep the button pressed until the following message is shown on the LCD: MENU SERWIS.
In order to exit the servicing functions, the user should switch the controller off and switch it on again
after a while.
Alarm Sound
VI.a)
This option enables the user to switch on or off the acoustic
sound signal when the alarm is activated.
Damping
VI.b)
This function is used to set the time after which the fan is
switched off if the boiler's temperature drops below the
damping threshold plus hysteresis 2°C. It means that if the
damping threshold is defined at 40ºC, this time is measured
not from the temperature of 40ºC but 38ºC.
Alarm Sound
Damping
Firing-Up Alarm Time
Minimum Pre-Set CH
Fan Threshold
DHW Pump Summer
Maximum Pre-Set DHW
Priority Temperature
Emergency CH Pump Activation
Alarm Temperature
Blow Gear
CH pump Room
11
ST-81 v 81.035
Yes
Fact. settings
Alarm sound
Damping
10 minutes
Damping
No