CHECK PLUGS & SEALS
Refer to Figure 33
In order to gain access to the check plugs (24
& 25), it is necessary to remove the plug seals
(26). This is accomplished by inserting a seal
hook or puller into, and through, one of the
insertion points (rectangular recesses) on the
plug seal, refer to figure 31. After successfully
removing the plug seals, discard and replace
with new seals.
Figure 33, Plug Seal (26)
ZT-2800
/ZT-3100
/ZT-3200
®
®
Insertion Area
/ZT-3400
TM
®

CYLINDER BLOCKS

Refer to Figure 34
Inspect each component of the cylinder block
assemblies for wear or damage. Inspect the
cylinder block's running surface for scratches
or galling. Replace if necessary.
NOTE: During separation of the cylinder
blocks, take care not to damage the
surfaces of the pistons and block.
Apply a thin coating of oil to all compo-
nents of the cylinder block assemblies
before reassembly.
After reassembling the cylinder block compo-
nents, set aside until ready for installation of
the center section and swashplate. Refer to
pages 30 and 31.
Figure 34, Pump/Motor Cylinder Block Assembly
Pistons
Piston Seats
Springs
Cylinder Block
37