Termination Location And Vent Information; Chimney Diagram - Outdoor Lifestyles TWILIGHT-II-MOD Installation Manual

Hide thumbs Also See for TWILIGHT-II-MOD:
Table of Contents

Advertisement

4 4

Termination Location and Vent Information

A. Chimney Diagram
C
FP
B
J
FP
D
FP
= AREA WHERE APPLIANCE IS NOT PERMITTED
X
= AIR SUPPLY INLET
A
= 0 inches...................clearances above grade, veranda,
B
= 12 inches.................clearance to window or door that
C
= 35-5/16 inches ........clearance below unventilated soffi t
35-5/16 inches ........clearance below ventilated soffi t
64-5/16 inches ........clearance below vinyl soffi ts and
D
= 9 inches...................clearance to outside corner
E
= 12 inches.................clearance to inside corner
F
= 3 ft. (Canada) ..........not to be installed above a gas me-
G
= 3 ft ...........................clearance to gas service regulator
H
= 9 inches (U.S.A)
12 inches (Canada) .clearance to non-mechanical (un-
i
= 3 ft. (U.S.A.)
6 ft. (Canada) ...........clearance to a mechanical (pow-
All mechanical air intakes within 10 feet of a termination cap
must be a minimum of 3 feet below termination.
J
= 54 in. ...................... On public property: clearance
A vent shall not terminate directly above a sidewalk or paved
driveway which is located between two single family dwellings
and serves both dwellings.
K
= 6 inches................. clearance from sides of electrical
L
= 12 inches................ clearance above electrical service
Location of the vent termination must not interfere with access to the
electrical service.
M
= 35-5/16 inches ............clearance under veranda, porch, deck,
64-5/16 inches .......vinyl or composite overhang
Permitted when veranda, porch, deck or balcony is fully open
on a minimum of 2 sides beneath the fl oor.
Figure 4.1 Minimum Clearances for Termination
Outdoor Lifestyles by Hearth & Home Technologies • Installation Manual TWILIGHT-II-MOD • 2290-970 Rev. H • 5/14
F
B
B
FP
FP
A
FP
= APPLIANCE OPENING
porch, deck or balcony
may be opened, or to permanently
closed window
electrical service
ter/regulator assembly within 3 feet
horizontally from the center-line of
the regulator
vent outlet
powered) air supply inlet, combus-
tion air inlet or direct-vent termina-
tion
ered) air supply inlet
above paved sidewalk or a paved
driveway.
service
balcony or overhang
H or i
X
FP
G
H
M
FP
FP
H
FP
(Spaces open only on one side and with an overhang)
N
= 6 inches ........... non-vinyl sidewalls
O
= 18 inches ......... non-vinyl soffi t and overhang
P
= 8 ft.
TWILIGHT-II-B
1 additional terminations
2 additional terminations
3 additional terminations
This appliance is approved for installation onto screened porches
with the following guidelines:
Minimum porch area: 96 square feet
Minimum ceiling height: 92 inches
Minimum two walls must be screened
Minimum top of screen height, side walls: 6 ft. 8 in.
Minimum screen area: 64 square feet
NOTE: There may be some odor and small amounts of soot
associated with venting the TWILIGHT-II-MOD onto a screened
porch. Ensuring good cross draft ventilation and routine maintenance
of the appliance will maximize comfort and cleanliness.
CAUTION! Risk of Burns! Terminations are HOT, consider
proximity to doors, traffi c areas or where people may
gather (sidewalk, deck, patio,
Local codes or regulations may require different clearances.
Vent system termination is permitted in porch areas with
two or more sides open.
Hearth & Home Technologies assumes no responsibility
for the improper performance of the appliance when the
venting system does not meet these requirements.
Vinyl protection kits are suggested for use with vinyl siding.
O
P
R
V
FP
L
A
K
Electrical
V
Service
C
V
Covered Alcove Applications
12 inches ......... vinyl sidewalls
42 inches ......... vinyl soffi t and overhang
Q
MIN
10 feet
Q + 3 feet
Q + 6 feet
Q + 9 feet
R
= (2 / # caps plus appliance) x Q
MAX
etc.).
N
FP
Q
K
V
R
MAX
2 x Q
ACTUAL
1 x Q
ACTUAL
2/3 x Q
ACTUAL
1/2 x Q
ACTUAL
ACTUAL
pass or
11

Advertisement

Table of Contents
loading

Table of Contents