will be reset to factory defaults are: The Ice Sensor will be set to ON, Ice
Low Temperature will be set to 10C, the Size Default will be set to Revert
to Small, the ice buster will be set to ON, the Ice Buster Interval will be
set to 30 minutes, and the Ice Buster Duration will be set to 6 seconds.
7.7

Locking the Machine:

This feature allows the manager/owner to lock the machine out of use by other
employees without the use of a code. The manager/owner can decide and change
the lockout code at will.
7.7.1 Change or set machine lock out code:
Enter 7-7-8-GO on the keypad. The screen will then read, "Enter Code:".
Enter the current code (the factory default is 0) and press GO. The screen
now reads, "New Code:". Enter the new one to four digit code that is
desired and press GO. The screen then reads, "Re-Enter:" Re-enter the
desired code and press GO.
7.7.2 Lock Machine:
To lock the machine press 7-7-7-GO. This will disable all functions
except for the ice buster. The screen will say, "Enter Code:". The
machine will not work until the correct security code is entered and the
GO button is pressed.
7.7.3 Write your code down and hide it in case you forget. If you do forget your
code and cannot find where you have it written down call us for assistance
at 1-800-253-6383.
7.7.4 Alcohol Pumps:
If your machine was set up to include alcohol pumps you can lock them
specifically. This feature allows pumps 6, 7, and 8 to be locked so that
product cannot be dispensed by using the Juice button. The factory default
is such that Pump 6, 7, and 8 are all unlocked. You can also change the
code that locks/unlocks the pumps.
7.7.4.1 They can be locked or unlocked individually by entering 3-5-3-GO
7.7.4.2 Enter the Alcohol Pump lockout code, the factory default is 0, and
7.7.4.3 The screen will now read, "Pump 7 Unlocked" or "Pump 7
7.7.4.4 The screen will now read, "Pump 8 Unlocked" or "Pump 8
7.7.4.5 Once the pumps have be configured, the menu can be exited by
7.7.4.6 To change the alcohol pump lockout code enter 3-5-2-GO on the
7.7.4.7 The screen will then read, "Enter Acode:". Enter the current code
OWN-003 Model BDI Owner's Manual – Blender Dispenser with Ice
on the keypad.
press GO. The screen will read, "Pump 6 Unlocked" or "Pump 6
Locked". Which ever is the case, it can then be changed to the
other by either pressing the S button or the M button and press the
GO button.
Locked". Make a selection by using the S or M button and then
press GO again to make a selection.
Locked". Make a selection by using the S or M button and then
press GO again to make a selection.
pressing the STOP button.
keypad.
(the factory default is 0) and press GO.