Changing The Drink Size Ratio; Advanced Programming; Calibration - K-Tec BLENDTEC BDI Owner's Manual

Blender dispenser with ice
Table of Contents

Advertisement

6.7.4 Pause is again, in whole seconds. Enter the value with the number keys on
the control panel and press GO.
6.8

Changing the Drink Size Ratio:

6.8.1 You can set the drink sizes for the S, M and L buttons on the keypad.
6.8.2 To access the menu, press 7-8-8-GO on the control pad (from the Enter
Drink # screen).
6.8.3 The display will now read "Size Small XX". Enter the size, in ounces, of
the small drink you want to make and press GO.
6.8.4 The data set will automatically move to the Size Medium data set; enter
the ounces size of your medium drink and press GO.
6.8.5 The data set will automatically move to the Size Large data set; enter the
ounces size of your large drink and press GO.
6.8.6 It is not necessary to have all three sizes, but you must have a "small"
drink. The "small" drink size correlates directly with the data set
programmed into the 7-8-9-GO menu. This is very important! If you set
your 7-8-9-GO menu pump, ice and water values to make a 12 ounce
drink and your small size to 14 you will only make 12 ounce drinks and
the M and L drinks will not turn out correct. The microprocessor uses the
small drink size and the settings in the 7-8-9-GO menu to automatically
generate your M and L drinks. Ensure that the size of drink and the
programmed data sets match directly.
6.8.7 Press the STOP button twice to exit the drink size menu.
Section 7: Advanced Programming_________________________________
This section is intended for the owner/manager of the location who will take the time to
fully understand the system and the information contained herein. Greater detail is spent
on controls and reports the unit can supply. All functions are accessed by pressing 7-8-9-
GO on the control panel unless otherwise noted.
7.1

Calibration:

There are two ways to optimize the drinks made in the BDI. You can use the trial
and error method, which involves making small changes to a drink and testing
each change as you go until you get it the way you want it. Or, you can calibrate
the BDI and make drinks according to a formula. Because fittings, tubing,
temperature, and product can all cause the pumps to dispense at different rates,
each drink you wish to make from a formula will require a calibrated pump. This
section will tell you how to isolate and calibrate each dispensing function
7.1.1 Press 7-8-9-GO to access the program mode. (If you have not read
Sections 6, do so now.)
7.1.2 Press 0 then GO. This will zero out the pump run time for Pmp 1 in Drink
1. The display will now read "Drink 1 Pmp 0."
7.1.3 Press 0 and GO until all eight pumps are at 0. Continue to zero out water,
ice and the blend times (you cannot zero out the cycles).
OWN-003 Model BDI Owner's Manual – Blender Dispenser with Ice
15

Advertisement

Table of Contents
loading

Table of Contents