Step eight: Bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
2. Reserve a certain length of drain hose
and power cord for installation when
binding them. When binding to a certain
degree, separate the indoor power and
then separate the drain hose.
3. Bind them evenly.
4. The liquid pipe and gas pipe should be
bound separately at the end.
Note:
• The power cord and control wire cannot be crossed or winding.
• The drain hose should be bound at the bottom.
Step nine: Hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
indoor
wall pipe
Note:
• Do not bend the drain hose too excessively in order to prevent blocking.

Configuration of Connection Pipe

1. Standard length of connection pipe
• 5 m, 7.5 m, 8 m.
2. Minimum length of connection pipe 3 m.
3. Maximum length of connection pipe.