Installation Of Indoor Unit - Toyotomi TRN-2122ZR User Manual

Wall mounted air conditioner inverter type
Table of Contents

Advertisement

Installation of indoor unit

Step one: Choosing installation location
Recommend the installation location and confirm it with client.
Step two: Install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the level
meter and then point out the screw fixing holes on the wall.
2. Drill the screw fixing holes on the wall with impact drill (the specifications of drill head
should be same as the plastic expansion particle) and then fill the plastic expansion
particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws and then check if the
frame is firmly installed by pulling the frame. If the plastic expansion particle is loose,
please drill another fixing hole nearby.
Step three: Open piping hole
1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame, shown as
below.
Space to
the wall
above
150mm
Left
Φ55mm
Φ70mm
2. Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet pipe posi-
tion. In order to drain smoothly, slant the piping hole on the wall slightly downward to
the outdoor side with the gradient of 5-10°.
Note:
• Pay attention to dust prevention and take relevant
safety measures when opening the hole.
• The plastic expansion particles are not provided
and should be bought locally.
Step four: Outlet pipe
1. The pipe can be led out in the direction of right,
rear right, left or rear left.
wall
(Rear piping hole)
(for some moddels)
Mark in the middle of it
Level meter
(Rear piping hole)
Indoor
5-10º
right
27
Wall
Space to
the wall
above
150mm
Right
Φ55mm
Φ70mm
Outdoor
Φ55
Φ70
rear left
left
rear right
GB

Advertisement

Table of Contents
loading

Table of Contents