Page 3
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 Important Information Information contained in this publication regarding this device’s applications and the like, is provided only for your convenience and may be superseded by updates.
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 Preparation Required Tools The OverWatch™ has been designed to be fitted using basic workshop tools. Shown below is a list of tools required...
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 Installation Instructions Operator Sensor Step Description Diagram 1. Remove the front panel from the outer metal enclosure.
Page 7
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 3. Drill one 5mm hole to install the P-clip as shown in the image.
Page 8
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 5. Drill a 20mm hole to install the operator sensor cable gland as shown in the image.
Page 9
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 7. Mount the operator sensor to the bracket by using M4 washers and security bolts.
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 Control Module Step Description Diagram 1. Mount the ECU inside the enclosure by using M4 screws and washers.
Page 11
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 3. Joystick and power: Disconnect the 9-pin connectors from the...
Page 12
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 Drive Select: At the back the LED circuit...
Page 13
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 Elevate Select: At the back the LED circuit...
Page 14
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 Connect the 8-pin connector from the Operator Sensor and the...
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 Post Installation Configuration Overview After the OverWatch™ has been installed it must be configured with the parameters to suit the machine. Follow the instructions below to configure the OverWatch™.
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 Installation Test After the model configuration has been set or updated an Installation Test must be performed. This will ensure the installation has been correctly performed and the OverWatch™...
To reconfigure the OverWatch™ for a different model requires an authorisation password to be supplied by a service manager. The authorisation password is generated from the EQSS website. The EQSS website requires a login username and password. If you are a service manager and don’t have a username and password, contact EQSS to register.
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 System Settings Default Settings See the sections below for details on each of the JLGxx94RT OverWatch™ system default settings.
EQUIPMENT SAFETY SYSTEMS JLG xx94RT Series 75 Naxos Way, Keysborough 3173 Victoria Australia P: +61 3 8770 6555 E: support@eqss.com.au Installation Manual REV 1.1 15/09/2023 Model6253 OverWatch™ Installation Manual Document # DO001627 Setting Name Description Default throttle_time Period after the trigger is pressed, the system does not track velocity.
Need help?
Do you have a question about the OverWatch JLG 94RT Series and is the answer not in the manual?
Questions and answers