Hide thumbs Also See for IMPULS Series:

Advertisement

Quick Links

operating manual
fireplace insert
DEFRO HOME IMPULS series
model
SM
ME
version
BL
BP
translation of original operating manual
edition 8
February 2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IMPULS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Defro Home IMPULS Series

  • Page 1 DEFRO HOME IMPULS series model version translation of original operating manual edition 8 February 2022...
  • Page 2 This Declaration of Conformity becomes invalid if any changes have been made to the DEFRO HOME IMPULS Fireplace, if its construction has been changed without our permission or if the fireplace is used not in accordance with the operating manual. This Declaration shall be handed over to a new owner along with the title of ownership of the fireplace.
  • Page 3 Dear Customer, Dear Customer, We would like to thank you for choosing the high-quality DEFRO prod- We would like to inform you that we make every effort to offer the uct which will ensure your safety and operational reliability. products of quality fulfilling the most restrictive standards and warrant- As our customers, you can always count on the help of the DEFRO ing operational safety.
  • Page 4: Table Of Contents

    Table of contents INFORMATION ........................................5 BASIC SAFETY RULES ....................................... 5 2.1. Safety warnings ......................................5 2.2. Warnings related to operation ..................................6 INTENDED USE ........................................6 TECHNICAL SPECIFICATION ..................................... 6 4.1. Design ........................................6 4.2. TECHNICAL DATA ....................................7 4.3.
  • Page 5: Information

    2. BASIC SAFETY RULES 1. INFORMATION 2.1. SAFETY WARNINGS The operating manual is an integral and essential part of the prod- uct and must be forwarded to the user also in case when the property • The national and local provisions should be met. is transmitted.
  • Page 6: Warnings Related To Operation

    Body (1, picture 1) of the DEFRO HOME IMPULS fireplace insert ter curing under the influence of heat (after several ig- is a steel jacket, with a combustion chamber located inside (2). Floor nitions).
  • Page 7: Technical Data

    4.2. TECHNICAL DATA Table 1. Technical data for the DEFRO HOME IMPULS fireplace inserts. Parameters unit DEFRO HOME IMPULS SM DEFRO HOME IMPULS ME Nominal power Flue size Efficiency 80.2 83.8 Seasonal energy efficiency CO emission for 13% O 0.0773 0.08...
  • Page 8: Equipment

    Picture 4. Dimensions fireplace insert DEFRO HOME IMPULS SM in Picture 4 Dimensions fireplace insert DEFRO HOME IMPULS ME in version BP and BL (mirror reflection of the BP version). version BP and BL (mirror reflection of the BP version).
  • Page 9: Working Environment

    Wall wooden blocks. Facade of the fireplace insert DEFRO HOME IMPULS fireplace insert should be in- stalled in compliance with the requirements of the cur- insulation rently applicable standards and legal regulations and side the hou- ding made of the detailed regulations of the target country.
  • Page 10: Hot Air Distribution System

    If several inserts are to be used in one room the air Using the gravity system you should use properly insulated and demand should be met for each insert. short (not exceeding 3 m) distributing ducts. For this system, it is not recommended to distribute hot air to too many rooms.
  • Page 11: Usage And Operation

    the pipe), with possible additional insulation using proper materials During the initial period after installation, the fireplace insert should (thickness 1.3 - 5 cm, heat conductivity min. 0.07 W/m °K). be operated with power equal to approx. 30% of rated power and in- As an alternative it is recommended to use insulated industrial crease temperature gradually.
  • Page 12: Damping

    sity of the combustion process should be set with the “air inflow adjust- 7. CLEANING AND MAINTENANCE ment slider”. Correct flame should have a light-yellow color and length of approx. 20-40 cm, depending on power of the boiler, after approx. 2- All operations related to the cleaning of all compo- 3 minutes from charging.
  • Page 13: Doors/Gaskets

    The sponge is intended only to clean the glass panes, it should not be used for gaskets or metal parts. It is not suitable for cleaning of glass panes with pyrolysis. The sponge may be used several times, depending on the degree of soiling of the glass pane. Use the gray side for cleaning and brush it off each time after use.
  • Page 14: Window Panel Dismantling

    7.4. WINDOW PANEL DISMANTLING It is possible to disassemble the window panel after the doors have been disassembled. The best way is to disassemble the window panel when the doors are in a horizontal position (e.g. when such doors lie on the table).
  • Page 15: Shutting The Stove Down

    Insufficient heating or damping: • too low amount of fuel in a furnace (charge furnace in com- pliance with the manual); • too high moisture content of wood used for combustion (use wood with moisture content <20%) large part of obtained en- ergy lost in water evaporation process: •...
  • Page 16: Remarks On Fireplace Insert Usage

    scrap. Take safety precautions during disassembly of the insert by us- The Purchaser receives Warranty Terms and Conditions, War- ing appropriate hand-held and mechanical devices as well as personal ranty Card as well as Operating Manual containing conditions for protective equipment (gloves, clothes, apron, glasses, etc.). boiler's usage, installation guide and parameters regarding the chimney, fuel and boiler water.
  • Page 17: Warranty Conditions "48H Service

    14) If the Guarantor, despite being ready to carry out the repair, will 23) During the execution of the warranty repair the customer is re- not be able to carry out the warranty repair twice because of the sponsible for securing the location of repair, including the system reasons attributable to the Purchaser then it is assumed that Pur- of fireplace insert, adjacent floor, walls etc.
  • Page 18 enclosed expertise protocol. At the same time we inform, that lack of payment for the invoice including the above-mentioned costs within 14 days from its issuance results in irrevocable loss of war- ranty for the used equipment and this information will be entered into our computer supervision system for equipment within the warranty period.
  • Page 19: Warranty Card

    WARRANTY CARD Confirmation of equipment's quality and completeness In accordance with the conditions stated herein, warranty for a fireplace insert of series has been issued DEFRO HOME IMPULS ............ operated in accordance with the operating manual. Equipment manufacturing number* ......................
  • Page 20: Carried Out Warranty Repairs And Maintenance

    14. CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE. fault description, repaired element, Stamp and signature date comments description of repairs of Service 20 | Page...
  • Page 21: Warranty Card (Copy To Send Back)

    WARRANTY CARD Confirmation of equipment's quality and completeness In accordance with the conditions stated herein, warranty for a fireplace insert of series has been issued DEFRO HOME IMPULS ............ operated in accordance with the operating manual. Equipment manufacturing number* ......................
  • Page 22 22 | Page...
  • Page 23: Complaint Form

    16. COMPLAINT FORM COMPLAINT FORM made on ........... in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ..........Equipment manufacturing date: ..........Equipment serial no.: ..........Equipment purchase date: ..........CLAIMANT Name and surname: ................................... Detailed address: ..................................................................
  • Page 24 24 | Page...
  • Page 25: Complaint Form

    17. COMPLAINT FORM COMPLAINT FORM made on ........... in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ..........Equipment manufacturing date: ..........Equipment serial no.: ..........Equipment purchase date: ..........CLAIMANT Name and surname: ................................... Detailed address: ..................................................................
  • Page 26 26 | Page...
  • Page 27: Complaint Form

    18. COMPLAINT FORM COMPLAINT FORM made on ........... in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ..........Equipment manufacturing date: ..........Equipment serial no.: ..........Equipment purchase date: ..........CLAIMANT Name and surname: ................................... Detailed address: ..................................................................
  • Page 28: Register Of Inspections Of Smoke Duct

    19. REGISTER OF INSPECTIONS OF SMOKE DUCT date stamp and signature of chimneysweep date stamp and signature of chimneysweep 28 | Page...
  • Page 29 29 | Page...
  • Page 30 30 | Page...
  • Page 31 Directive of the European Parliament and the Council 2009/125/EC Equipment parameters Model identifier(s): DEFRO HOME IMPULS SM, DEFRO HOME IMPULS SM BP, DEFRO HOME IMPULS SM BL, DEFRO HOME IMPULS SM G, DEFRO HOME IMPULS SM BP G, DEFRO HOME IMPULS SM BL G Indirect heating function: [yes/no] Direct thermal output: 8.2 (kW)
  • Page 32 Properties in the case of operation only with recommended fuel Parameter Designa- Value Unit Parameter Designa- Value Unit tion tion Thermal output Performance (calorific value in operating condition) Rated heat out- Performance at 80.2 η th,nom rated thermal power Minimum heat Performance at η...
  • Page 33 Directive of the European Parliament and the Council 2009/125/EC Equipment parameters Model identifier(s): DEFRO HOME IMPULS ME, DEFRO HOME IMPULS ME BP, DEFRO HOME IMPULS ME BL, DEFRO HOME IMPULS ME G, DEFRO HOME IMPULS ME BP G, DEFRO HOME IMPULS ME BL G Indirect heating function: [yes/no] Direct thermal output: 9.9 (kW)
  • Page 34 Properties in the case of operation only with recommended fuel Parameter Designa- Value Unit Parameter Designa- Value Unit tion tion Thermal output Performance (calorific value in operating condition) Rated heat out- Performance at 83.8 η th,nom rated thermal power Minimum heat Performance at η...
  • Page 35 35 | Page...

Table of Contents