  • Page 1 DEFRO HOME PORTAL series model translation of original operating manual edition 8 February 2022...
  • Page 2 This Declaration of Conformity becomes invalid if any changes have been made to the DEFRO HOME PORTAL Fireplace, if its construction has been changed without our permission or if the fireplace is used not in accordance with the operating manual. This Declaration shall be handed over to a new owner along with the title of ownership of the fireplace.
  • Page 3 Dear Customer, Dear Customer, We would like to thank you for choosing the high-quality DEFRO prod- We would like to inform you that we make every effort to offer the uct which will ensure your safety and operational reliability. products of quality fulfilling the most restrictive standards and warrant- As our customers, you can always count on the help of the DEFRO ing operational safety.
  • Page 4: Table Of Contents

    Table of contents INFORMATION ........................................5 BASIC SAFETY RULES ....................................... 5 2.1. Safety warnings ......................................5 2.2. Warnings related to operation ..................................6 INTENDED USE ........................................6 TECHNICAL SPECIFICATION ..................................... 6 4.1. Design ........................................6 4.2. TECHNICAL DATA ....................................7 4.3.
  • Page 5: Information

    2. BASIC SAFETY RULES 1. INFORMATION 2.1. SAFETY WARNINGS The operating manual is an integral and essential part of the prod- • The national and local provisions should be met. uct and must be forwarded to the user also in the case when the prop- •...
  • Page 6: Warnings Related To Operation

    • Internal parts of the fireplace insert should not be Body (1, pictures 1, 2, 3) of the DEFRO HOME PORTAL fireplace washed with water. insert is a steel jacket, with a combustion chamber located inside (2).
  • Page 7: Technical Data

    4.2. TECHNICAL DATA Table 1. Technical data for the DEFRO HOME PORTAL fireplace in- serts. Parameter name unit value Nominal power 12.0 Flue size Diameter of air intake socket Efficiency 80.5 Seasonal energy efficiency CO emission for 13% O 0.0678 Combustion temperature °C...
  • Page 8: Spare Parts

    5.2. WORKING ENVIRONMENT the efficiency and has an adverse influence on dry DEFRO HOME PORTAL fireplace insert should be in- stove lifetime. stalled in compliance with the requirements of the cur-...
  • Page 9: Hot Air Distribution System

    Fireplaces in the G version are not intended for a so-called “hot” installation due to the required cooling of the doors mechanism. Instal- lation of the DEFRO HOME INTRA G fireplace insert in such a system will void the warranty. It is indicated to use a bigger expansion joint, in...
  • Page 10: Forced System For Hot Air Distribution

    5.3.2. FORCED SYSTEM FOR HOT AIR DISTRIBUTION The DEFRO HOME PORTAL fireplace insert offers several options to connect the air intake: from the back and from the right and left side. kratka wentylacyjna The connection of the air duct to the fireplace insert is implemented wylot gorącego...
  • Page 11: Usage And Operation

    A chimney or individual smoke duct should meet the following require- It is forbidden to use other materials than described ments: in this manual for firing up, in particular flammable • chemicals such as: oil, petrol, solvents and others. be resistant to combustion products, water-proof and suitably insulated, in compliance with conditions of use, •...
  • Page 12: Damping

    amount of such smoke is considerable and lasts for a whole duration of doors opening then it is absolutely required to check possible causes acc. to the guidelines given in chapter 8. You should control the level of filling of the container with ash. Overfilling of containers results in a lack of cooling of the grate and limits air supply for combustion.
  • Page 13: Removal Of Deflector Made Of Vermiculite And Heat-Resistant Cladding From The Furnace Chamber

    7.1.5. REMOVAL OF DEFLECTOR MADE OF VERMICULITE AND 7.1.6. FLUE HEAT-RESISTANT CLADDING FROM THE FURNACE In compliance with applicable regulations, you should clean the CHAMBER flue twice (2) a year. Flue should be cleaned by a chimnysweep com- pany and this fact should be documented in this manual. Flue gases coming out of the blocked chimney are dan- gerous.
  • Page 14: Measures In Case Of Fire In The Flue /Soot Ignition

    5 years for the correct operation of the equipment, solid fuel (e.g. tourist), paper can be used etc. 2 years for doors lifting system for DEFRO HOME PORTAL Flammable materials must not be placed on the fireplace insert fireplace inserts in the G version (guillotine), and in its vicinity.
  • Page 15 2 years for claddings made of heat-resisting concrete - identification of product will be impossible (that is conformity Ceramiton, while the warranty does not cover discolora- of the presented product with a document describing the tions, a complete change of the color or degradation of top equipment, replaced or illegible documents), layer of the coating.
  • Page 16: Warranty Conditions "48H Service

    25) Provisions of this document do not limit in any way authorizations resulting from the claim submitted on the basis of statutory war- ranty. The warranty also had no influence on the other clamps of the Purchaser, according to the provisions of law - including these concerning non-conformity of the goods with the contract.
  • Page 17: Warranty Card

    13. WARRANTY CARD WARRANTY CARD Confirmation of equipment's quality and completeness In accordance with the conditions stated herein, warranty for a fireplace insert DEFRO HOME PORTAL type ..........operated in accordance with the operating manual has been issued. Equipment manufacturing number* ......................
  • Page 18: Carried Out Warranty Repairs And Maintenance

    CARRIED OUT WARRANTY REPAIRS AND MAINTENANCE. fault description, repaired element, Stamp and signature date comments description of repairs of Service 18 | Page...
  • Page 19: Warranty Card (Copy To Send Back)

    15. WARRANTY CARD (COPY TO SEND BACK) WARRANTY CARD Confirmation of equipment's quality and completeness In accordance with the conditions stated herein, warranty for a fireplace insert DEFRO HOME PORTAL type ..........operated in accordance with the operating man- ual has been issued. Equipment manufacturing number* ......................
  • Page 20 20 | Page...
  • Page 21: Complaint Form

    16. COMPLAINT FORM COMPLAINT FORM made on ........... in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ..........Equipment manufacturing date: ..........Equipment serial no.: ..........Equipment purchase date: ..........CLAIMANT Name and surname: ................................... Detailed address: ..................................................................
  • Page 22 22 | Page...
  • Page 23: Complaint Form

    17. COMPLAINT FORM COMPLAINT FORM made on ........... in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ..........Equipment manufacturing date: ..........Equipment serial no.: ..........Equipment purchase date: ..........CLAIMANT Name and surname: ................................... Detailed address: ..................................................................
  • Page 24 24 | Page...
  • Page 25: Complaint Form

    18. COMPLAINT FORM COMPLAINT FORM made on ........... in connection with complaint no......SUBJECT OF COMPLAINT EQUIPMENT TYPE: ..........Equipment manufacturing date: ..........Equipment serial no.: ..........Equipment purchase date: ..........CLAIMANT Name and surname: ................................... Detailed address: ..................................................................
  • Page 26: Register Of Inspections Of Smoke Duct

    19. REGISTER OF INSPECTIONS OF SMOKE DUCT date stamp and signature of chimneysweep date stamp and signature of chimneysweep 26 | Page...
  • Page 27 27 | Page...
  • Page 28 28 | Page...
  • Page 29 Equipment parameters Model identifier(s): DEFRO HOME PORTAL ME, DEFRO HOME PORTAL ME G, DEFRO HOME PORTAL ME BL, DEFRO HOME PORTAL ME BP, DEFRO HOME PORTAL ME BL G, DEFRO HOME PORTAL ME BP G, DEFRO HOME PORTAL ME C, DEFRO...
  • Page 30 Properties in the case of operation only with recommended fuel Parameter Designa- Value Unit Parameter Designa- Value Unit tion tion Thermal output Performance (calorific value in operating condition) Rated heat out- Performance at 80.5 η th,nom rated thermal power Minimum heat Performance at η...