Download Print this page
Airxcel 9330X713 Service Manual
Airxcel 9330X713 Service Manual

Airxcel 9330X713 Service Manual

Roof top air conditioners

Advertisement

SERVICE MANUAL
FOR
ROOF TOP AIR CONDITIONERS

Advertisement

loading
Need help?

Need help?

Do you have a question about the 9330X713 and is the answer not in the manual?

Questions and answers

Mark Aine
June 11, 2025

What coleman mach model should I buy to replace my 8000 series

Subscribe to Our Youtube Channel

Summary of Contents for Airxcel 9330X713

  • Page 1 SERVICE MANUAL ROOF TOP AIR CONDITIONERS...
  • Page 2 6757A7201 SERVICE TEST DEVICE This test device is an invaluable aid in quickly diagnosing repairs to all Airxcel, Inc. roof top air conditioners produced after 1979.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Basic Components ..........Air Handling .
  • Page 4 BASIC COMPONENTS AND THEIR FUNCTIONS REFRIGERATION SYSTEM DIAGRAM...
  • Page 5: Basic Components

    I. BASIC COMPONENTS Compressor Metering Device The compressor is called a hermetic compressor which The refrigerant enters the cap tube from the condenser as a means that it is completely sealed (welded together). It is, warm high pressure liquid. As the refrigerant flows therefore, not internally field serviceable.
  • Page 6: Electrical Power Circuits

    If there is a reading of 0 between any two leads, Filters the motor is shorted and is no good. If there is a reading of infinity (no meter reading at all) The filters should always be in place when the system is between any two leads, the winding is open and running.
  • Page 7: Capacitors

    Power Supply – Generated by on-board motor generator 115 volts (domestic USA) between the black and white leads, but there will be 0 volts between either lead and If the power supply for the recreational vehicle is supplied ground. by an on-board motor generator, its wiring may be identical to the commercial power described above.
  • Page 8: Free Delivery Ceiling Assemblies

    VI. FREE DELIVERY CEILING ASSEMBLIES Selector Switch – Free Delivery Ceiling Assemblies the electric heater when the selector switch is in the heating position. The thermostat is actuated by sensing the The selector switch is mounted on the left side of the temperature of the return air through the vent where the interior ceiling assembly.
  • Page 9: Service Problems And Their Possible Solutions

    VII. SERVICE PROBLEMS AND THEIR POSSIBLE SOLUTIONS SERVICE PROBLEMS WITH AIR CONDITIONER AND FREE DELIVERY CEILING ASSEMBLIES The following list of service problems covers only some of the more common problems which may occur and lists only the more probable causes. In many instances, it will be necessary to use the wiring diagram in this manual to check out the electrical circuits step by step, starting at the power source.
  • Page 10: Typical Wiring Diagrams

    WIRING DIAGRAMS 9330X713, 9330X714 COOL ONLY CEILING ASSEMBLIES 9330X715, 9330X916 HEAT/COOL CEILING ASSEMBLIES...
  • Page 11 7000 SERIES ROOF MOUNT AIR CONDITIONERS...
  • Page 12 8000 SERIES ROOF MOUNT AIR CONDITIONERS 9000 SERIES ROOF MOUNT AIR CONDITIONER...
  • Page 13 Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976G141 (12-11)