Connecting The Water Supply - Miele FNS 28463 E bb Operating And Installation Instructions

Table of Contents

Advertisement

Connecting the water supply

Before establishing the mains water
connection, ensure that the appli-
ance is disconnected from the power
supply.
Ensure that it is screwed into posi-
tion correctly.
Ensure that the connections are tight
and leak-proof.
Before using the appliance for the
first time, the water supply pipework
should be purged of air by a qualified
and competent person.
A stopcock  with a metric R3/4
thread must be incorporated when
connecting to the water supply.
The solenoid valve  is located at the
back of the appliance at the bottom. It
also has a metric R3/4 connection.
 Unscrew safety cap from nut  on
the straight end of the hose .
 Connect this nut  using the tool 
supplied to the stopcock . Tighten
the nut by turning it clockwise until
the maximum torque is reached and
the tool  is over-torqued.
Mains water connection
 Briefly open the stopcock  to vent
the pipework, and fill the pipework
with water. Place the end of the hose
in a bucket when doing this.
 Pull cover  off of the solenoid
valve .
 Push nut  over the angled end of
the hose  as far as it will go, hold-
ing the nut securely.
 Moisten the seal , then press the
seal into the nut.
The seal should lie flush with the angled
end of the hose and held lightly in posi-
tion.
Take care not to damage the
thread in the solenoid valve.
Position the nut carefully and screw it
into position.
 Connect the hose by the angled end
to the solenoid valve.
 Tighten the nut with the tool sup-
plied  by turning it clockwise until
the maximum torque is reached and
the tool  is over-torqued.
 Slowly open the stopcock , and
check the whole water system for
leaks.
 Fold the tab  on the tool  in, and
secure the tool to the stainless steel
hose for safe-keeping.