Maintenance - Cala CA300M Installation And Maintenance Manual

Counter current equipment or spas pumps
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
5.

MAINTENANCE

• If the pump stops, check that the motor amp consumption during his working is the same or
less than that indicated on the manufacturer's specification board, or failing him, contact the
nearest Customer Technical Service.
• Empty the pump in cases where it must remain without use for some time, mainly in cold
countries where there may be danger of freezing.
• To empty the pump, remove the draining plug from the pump body (see explosion drawing).
• The pump components which, due to its regular use, suffer wear and tear must be periodically
replaced in order to maintain a good performance of the pump.
The following table provides a list of fungible pump components and/or components that can
be damaged and their estimated lifetime.
COMPONENT DESCRIPTION
O-rings and sealing elements in general
mechanical seal
Ball bearings
The estimated period of life of the parts above has been established under normal conditions
of product installation.
Follow the instructions in the manual in order to maintain the estimated lifetime of the pump.
6.
DISMANTLING
• The motor unit may be dismantled from the pump body without needing to disconnect the
pump's suction and impulsion tubing.
• To disconnect the motor unit from the pump body, remove the screws that join them (see
explosion drawing).
_______________________________________________________________________________________________________________________
ESPAÑOL
IMPORTANTE: El manual que usted tiene en sus manos, contiene información fundamental acerca
de las medidas de seguridad a adoptar en el momento de la instalación y la puesta en servicio. Por
ello, es imprescindible que tanto el instalador como el usuario lean las instrucciones antes de pasar
al montaje y la puesta en marcha.
1.
PRESCRIPCIONES GENERALES DE SEGURIDAD
Esta simbología (
no respetar las prescripciones correspondientes.
PELIGRO. Riesgo de electrocución.
La no advertencia de esta prescripción comporta un riesgo de electrocución.
PELIGRO.
La no advertencia de esta prescripción comporta un riesgo de daño a las
personas o cosas.
LIFETIME ESTIMATE
1 year
1 year
1 year
) indica la posibilidad de peligro como consecuencia de
POSSIBLE BREAKDOWNS, CAUSES AND SOLUTIONS
PROBLEMS
CAUSES
Air entry in suction tube
Motor turning direction
THE PUMP DOES NOT PRIME
incorrect.(III)
Wrong voltage
PROBLEMS
CAUSES
Air entry in suction tube
Motor turning direction
incorrect.(III)
THE PUMP GIVES LOW FLOW
Load loss in suction
Wrong voltage
PUMP MAKES A NOISE
Incorrect fixation of the pump
PUMP WILL NOT START
Wrong voltage
THE MOTOR MAKES A
Blocked motor
NOISE BUT DOESN'T START
Increase in terminal box
temperature because of
voltage arch effect
Heat protector blows
THE MOTOR STOPS
Terminal boxes badly
connected
ATENCIÓN.
La no advertencia de esta prescripción comporta un riesgo de daños a la
bomba o a la instalación.
2.
NORMAS GENERALES DE SEGURIDAD
GENERALIDADES
• Las máquinas citadas en este Manual están especialmente diseñadas para obtener el
prefiltrado y la recirculación del agua en las piscinas.
• Están concebidas para trabajar con aguas limpias y de temperatura que no exceda 45C.
• La instalación debe ser efectuada de acuerdo con las indicaciones particulares de cada
implantación.
• Se deben respetar las normas vigentes para la prevención de accidentes.
SOLUTIONS
Check pipe fittings and suction tube joints
Invert two phases of the feeding line
Check that the network voltage corresponds to that on
the motor specification board
SOLUTIONS
Check pipe fittings and suction tube joints
Invert two phases of the feeding line
Prevent as much as possible, elements that produce
load loss
Check that the network voltage corresponds to that on
the motor specification board
Fix pump correctly
Check that the network voltage corresponds to that on
the motor specification board
Dismantle the motor and contact the technical service.
Check terminal box connections
Correctly connect cables with terminal box terminals
Fasten the cable to the terminal correctly
Modify size of connection cable to terminal box
terminals