Control Panel Indicators; Pressure Relief Procedure - Titan 805-016 Operating Manual

Airless, high-pressure spraying unit
Hide thumbs Also See for 805-016:
Table of Contents

Advertisement

Available languages

Available languages

Control Panel Indicators

The following is a description of the control panel indicators.
Motor Running
Indicator
RAPID
CLEAN
Pressure Indicator
The pressure indicator shows the current operating pressure of the
sprayer. It has three different indications: blinking yellow, solid
yellow, and solid green.
Blinking Yellow
When the pressure indicator is blinking yellow, the sprayer is
operating between 0 and 200 PSI. A blinking yellow pressure
indicator means:
• The sprayer is plugged in and turned "ON"
• The sprayer is at priming pressure (little or no pressure)
• It is safe to move the PRIME/SPRAY valve between positions
• It is safe to change or replace the spray tip
NOTE: If the pressure indicator begins blinking yellow
when the pressure control knob is set at a higher
pressure and the PRIME/SPRAY valve is in the
SPRAY position, either the spray tip is worn or the
sprayer is in need of service/repair.
Solid Yellow
When the pressure indicator is solid yellow, the sprayer is operating
between 201 and 1900 PSI. A solid yellow pressure indicator means:
• The sprayer is at the proper pressure setting for spraying stain,
lacquer, varnish, and multi-colors
• If the pressure indicator goes to solid yellow when the
pressure is set so that it starts at solid green, it indicates one of
the following:
a.
Tip Wear Indicator — when spraying with latex or at high pressure
the solid yellow appears. This means the tip is worn and needs to
be replaced.
b.
Tip Too Large — when a tip that is too large for the sprayer is put
in the gun, the pressure indicator will turn from solid green to solid
yellow.
c.
Fluid Section Wear — if a solid yellow pressure indicator appears
when using a new tip and the pressure is set at maximum, service
may be required (worn packings, worn piston, stuck valve, etc...).
Solid Green
When the pressure indicator is solid green, the sprayer is operating
between 1901 and 3300 PSI. A solid green pressure indicator means:
• The sprayer is at the proper pressure setting for spraying oil-
based and latex house paints
• The sprayer is operating at peak performance at a high
pressure setting
Motor Running Indicator
The Motor Running indicator is on when the motor is commanded to
run. This indicator is used by service centers to troubleshoot motor
problems.
English

Pressure Relief Procedure

Pressure Indicator
1. Lock the gun by pushing the gun trigger lock to the locked
2. Turn off the sprayer by moving the ON/OFF switch to the OFF
3. Turn the pressure control knob counterclockwise to its OFF
4. Unlock the gun by pushing the gun trigger lock to the
5. Hold the metal part of the gun
6. Trigger the gun to remove any
7. Lock the gun by pushing the gun
8. Move the PRIME/SPRAY valve
6
Be sure to follow the Pressure Relief Procedure when
shutting down the sprayer for any purpose, including
servicing or adjusting any part of the spray system,
changing or cleaning spray tips, or preparing for
cleanup.
position.
position.
position in the black zone.
unlocked position.
firmly to the side of a metal
container to ground the gun and
avoid a build up of static electricity.
pressure that may still be in the
hose.
trigger lock to the locked position.
down to the PRIME position.
© Titan Tool Inc. All rights reserved.

Advertisement

Table of Contents
loading

This manual is also suitable for:

805-000Impact 440805-019

Table of Contents