Control Panel Indicators; Digi-Trac™ Control System Operation - Titan 805-009 Owner's Manual

Airless sprayer
Hide thumbs Also See for 805-009:
Table of Contents

Advertisement

Available languages

Available languages

control Panel Indicators

The following is a description of the control panel indicators.
Motor
Running
Indicator
RAPID
CLEAN
Pressure Indicator
The pressure indicator shows the current operating pressure of
the sprayer. It has three different indications: blinking yellow,
solid yellow, and solid green.
Blinking yellow
When the pressure indicator is blinking yellow, the sprayer is
operating between 0 and 200 PSI. A blinking yellow pressure
indicator means:
• The sprayer is plugged in and turned "ON"
• The sprayer is at priming pressure (little or no pressure)
• It is safe to move the PRIME/SPRAY valve between
positions
• It is safe to change or replace the spray tip
NOTE: If the pressure indicator begins blinking yellow
when the pressure control knob is set at a
higher pressure and the PRIME/SPRay valve
is in the SPRay position, either the spray tip is
worn or the sprayer is in need of service/repair.
Solid yellow
When the pressure indicator is solid yellow, the sprayer is
operating between 201 and 1900 PSI. A solid yellow pressure
indicator means:
• The sprayer is at the proper pressure setting for spraying
stain, lacquer, varnish, and multi-colors
• If the pressure indicator goes to solid yellow when the
pressure is set so that it starts at solid green, it indicates
one of the following:
a. Tip Wear Indicator — when spraying with latex or at
high pressure the solid yellow appears. This means the
tip is worn and needs to be replaced.
b. Tip Too Large — when a tip that is too large for the
sprayer is put in the gun, the pressure indicator will turn
from solid green to solid yellow.
c. Fluid Section Wear — if a solid yellow pressure
indicator appears when using a new tip and the pressure
is set at maximum, service may be required (worn
packings, worn piston, stuck valve, etc...).
Solid Green
When the pressure indicator is solid green, the sprayer is
operating between 1901 and 3300 PSI. A solid green pressure
indicator means:
• The sprayer is at the proper pressure setting for spraying
oil-based and latex house paints
• The sprayer is operating at peak performance at a high
pressure setting
Motor Running Indicator
The Motor Running indicator is on when the motor is commanded
to run. This indicator is used by service centers to troubleshoot
motor problems.
NOTE: If the motor running and pressure indicators blink
alternately, it means the motor has overheated.
Turn pump OFF and allow to cool.
English
Digi-Trac™ control System Operation
The Digi-Trac™ Control System is an optional add-on that
increases the functionality of the sprayer. It is installed directly
below the pressure control knob on the control panel. It consists
of a display and four function keys. The display shows various
Pressure
menu screens that allow the user to customize and monitor
Indicator
sprayer operation using the function keys.
Function Keys
The function keys are numbered 1–4. Each key is labeled with
an additional function as well.
#1/Menu Key
Pressing the #1 key scrolls through the available menu screens
or performs a function described on the active menu screen.
#2/+ Key
Pressing the #2 key performs a function described on the active
menu screen or increases a value.
#3/- Key
Pressing the #3 key performs a function described on the active
menu screen or decrease a value.
#4/Select Key
Pressing the #4 key selects the active menu screen or performs
a function described on the active menu screen.
Menu Screens
Several menu screens are available for the user to customize
and monitor sprayer operation. They include Main Screen, User
Pre-Sets, Volume Pumped, Job Volume, Unit Serial #, TImers,
Job Timers, Service Time, Security Code, Prime, and RAPID
CLEAN.
Main Screen
The Main Screen is the default screen
for the control system at sprayer startup.
Pressing the #2 key switches between PSI and MPa units of
measure. Press the #1 key to scroll through the remaining menu
screens.
Gallons Pumped Screen
The Gallons Pumped screen shows the
total number of gallons or liters sprayed
by the sprayer.
To select the Gallons Pumped screen,
press the #4 key.
job volume Screen
The Job Volume screen allows the user
to reset a gallon counter to track usage
on specific jobs.
To select the Job Volume screen, press
the #4 key.
unit Serial # Screen
The Unit Serial # screen shows the
sprayers serial number.
To select the Unit Serial # screen, press
the #4 key.
6
SET PSI
Display
ACTUAL PSI
Function
Keys
© Titan Tool Inc. All rights reserved.
3000
2950
SET PSI
3000
ACTUAL PSI
2950
GALLONS PUMPED
MENU-1
SELECT-4
GALLONS
X
MENU-1
JOB VOLUME
MENU-1
SELECT-4
JOB GAL
XXXX
MENU-1
RESET-3
UNIT SERIAL #
MENU-1
SELECT-4
SER # XXXXXXXXXX
MENU-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Impact 840805-007805-008Impact 740805-010

Table of Contents