Maintenance And Troubleshooting - Pro's Kit MT-7071N User Manual

Lcd cable length toner & probe kit

Advertisement

Available languages

Available languages

current
Dimension
Remote Unit Specification
Connectors
Dimension
7. MAINTENANCE & TROUBLE SHOOTING
Warning:
• Turn off the Transmitter or Receiver and disconnect all test leads
before replacing the battery.
Caution:
• To avoid damaging the case, do not use solvents or abrasive
cleansers. Clean the case with a soft cloth dampened with water or
a mild soap solution.
Trouble shooting
Possible Problems
The signal from
Transmitter can not be
detected by receiver
No signal received
from Transmitter on
Live
202 × 50 × 32mm
RJ45× 1,BNC× 1
106×32×30mm
Trouble shooting
1. Shortage of battery power: Check
the battery on both Transmitter and
receiver. If the battery voltage is less
than 7.0V, please replace new battery
2. Make sure the switch position on
receiver is "SCAN" or "LED". The
SCAN function will not work if the
switch is at "NCV" position.
3. Device damaged: please return the
product to the place you purchased
the product for maintenance
There might be conflict between the
signal from telephone office and the
14