Ø
Auto-off time setting:
Adjust the Auto-off time among 15mins, 30mins, 1hour, off.
Ø
Contrast setting:
Press the "
key to adjust the contrast to suit yourself.
Ø
Version information:
To check version information of software and hardware. as above.

3.6 Non-contact Voltage detection (NCV)

This function is used to determine whether the wire or equipment has
an AC voltage, the detection range AC90-1000V (50 / 60Hz).
Ø
Push the receiver function switch to the NCV position, put the
receiver probe close to the target body, if the AC voltage is
detected, the speaker emits an alarm sound of different frequency,
the speaker rapid sound indicates a high voltage or fire line, the
slow sound may be low voltage or zero line.
-
" to setting. And press "
./0