HDMI installations. This portable device allows installers to quickly test, troubleshoot, and verify HDMI (high definition multimedia interface) cables. MT-7062 is designed to test wire circuit state of HDMI cables with Type A & C connectors conforming to 1.0, 1.1, 1.2, 1.2a, 1.3, 1.3a, 1.3b, 1.3c, 1.4, 1.4a Category 1 and...
1 x Pouch bag. Users’ Manual. FEATURES: The MT-7062 HDMI cable tester allows the fast and accurate verification both HDMI type A and Type C cables, mapping continuity and proper configuration and displays 19 pins and shield connection status on both master and remote unit.
Test interface of Remote unit:HDMI (type A) ×1pcs, Mini HDMI (type C) ×1 pcs. Cable length:Under 50 meters. Test Mode:Automatically fast scan、Automatically Slow scan、 Manual test for step by step. Displays:19 LEDs and shield LED on both master and remote unit.
HDMI Cable Wire / Pin And Signal Description: HDMI Mini-HDMI Signal Description (A)Pin # (C) Pin # Assignment Data 2﹢ TMDS Red Data Plus (Data 2 +) Data 2S TMDS Red Data Shield (Data 2 Shield) Data 2﹣ TMDS Red Data Minus (Data 2 –) Data 1﹢...
Page 6
Power off: Slide upper left switch to “OFF”,”POWER” LED will go out and the unit will no longer work when pushing the “TEST” button. Master unit loop continuity scan testing function Note When performing master unit scan test, sequence of LEDs light up as below.
Page 7
Open : with a short “beep” sound 。 No connected pins LED are off. Example: Test HDMI (A Type) to HDMI (A Type) cable that pin #2, #5, #8 and #11 are not connected , or test HDMI (A Type) to Mini-HDMI (C Type) cable that pin #1、#4、#7、#10 are not connected.
Page 8
Fig 4. Short Fig 5. Crossover Master unit with Remote unit automatic testing function ※ Insert one of A type connector of cable to Master unit MAIN (A Type) socket and insert the other one to Remote unit A Type connector for test HDMI cable A type to A type.
Page 9
Press “ TEST” button then Master unit and Remote unit both #1~19 and “Shield” LEDs will indicate tested result. Testing result will keep 12 seconds then all LEDs are off except “POWER”LED for saving power. LED indicates test result as below: ...
Page 10
Short:Master unit LED brighter than others and Remote unit LED off when scan to shorted pins, Master unit and Remote unit both LED are all lighted up in sequence, Example : Test HDMI (A Type) to HDMI (A Type) cable that pin #4、#5、#6 are shorted, or teat HDMI (A Type) to Mini-HDMI (C Type) cable that pin #4、#5、#6 are shorted, or test Mini-HDMI (C Type) to Mini-HDMI (C Type) cable that pin #4、#5、...
Page 12
Fig 9. Crossover Master unit with Remote unit fast continuity scan testing function: Press “ TEST” button during the slow continuity scan testing, or press three times“ TEST” button after the automatic testing LEDs are off : It will fast scan pin 1~19pin and Shield , Master unit and Remote unit both #1~19 and Shield LEDs will light up in sequence fast and sustained repeated automatic scan.
Page 17
TMDS Blue Data Plus Data 0﹢ (Data 0+) TMDS Blue Data Shield Data 0S (Data 0 Shield) TMDS Blue Data Minus Data 0﹣ (Data 0 –) Clock ﹢ TMDS Clock Plus (Clock +) TMDS Clock Shield (Clock Clock S Shield) TMDS Clock Minus Clock ﹣...
Page 18
主機自我迴路連續快速掃瞄測試: 注意 當「主機自我迴路連續快速掃描測試」結果顯示時,燈號掃描 順序是: #1 (Data 2﹢)→ #10 (Clock ﹢)→ #S (Shield)→ #11 (Clock S)。 ※ 測試 HDMI (A Type)對 HDMI (A Type)的線時:將線插入主機 LOOPBACK (A Type)接口和 MAIN (A Type)接口。 ※ 測試 HDMI (A Type)對 Mini-HDMI (C Type)的線時:將線插入主 機 LOOPBACK (A Type)接口和 Mini-HDMI (C Type)接口。 主機左上角開關,撥到...