Troubleshooting - TECHCON SYSTEMS TS6500CIM User Manual

Automatic techkit mixer
Table of Contents

Advertisement

Available languages

Available languages

10.

TROUBLESHOOTING

PROBLEM
Unit fails to start
LCD does not light
Air Cylinder does not
move
The hardener is not
completely injected
The injection rod does
not retract
Material is not
completely mixed
Cartridge holder is not
in "Home'' position
Mixing rod does not
reach spindle
No pressure on plunger
Plunger disk does not
fit inside cartridge
Cartridge holder
remains in the down
position during mixing
cycle
Motor is not running
POSSIBLE CAUSE
No power input
Emergency button is
pressed
Safety door is not
fully closed
No power input
Insufficient air
pressure
Air hoses not
plugged in
Regulator defective
Air cylinder is
damaged
Injection rod is dirty
Injection rod is bent
Not enough mixing
cycle
Insufficient air
pressure
Insufficient air
pressure
Air hoses not
plugged in
Extension spindle is
not installed for 6''
rod
Mixing rod in not
fully extended
Plunger air hose is
not connected
Wrong plunger disk
size
Sensor and magnet is
not aligned
No power to motor
Motor burned out
18
CORRECTION
Check power
connections
Release Emergency stop
button
Close safety door
Check power
connections
Check Fuse
Turn on power
Increase air pressure to
80 psi (5.5 bar)
Check air connection
Replace regulator
Replace air cylinder
Clean rod
Replace rod
Increase number of
cycles
Increase air pressure to
80 psi
Increase supply pressure
to 80 psi (5.5 bar)
Check air connection
Install extension spindle
for 6'' rod
Extend mixing rod
Connect plunger air hose
Use correct plunger disk
size
Turn off unit and adjust
sensor / magnet
alignment
Check motor connection
Replace motor

Advertisement

Table of Contents
loading

Table of Contents