4. Press the Setup button (↵) to activate the main cylinder (the
cartridge holder will move up and down)
ACTIVATE
INJECTION
ACTIVATE
Figure 14.0 Manual Mode Screen
7

SPEED CONTROL

7.1 For main air cylinder
The main air cylinder drives cartridge kit up and down. The
stroke speed of the main air cylinder can be adjusted by rotating
the flow control screw (Fig. 15) clockwise to increase the speed
and counterclockwise to decrease the speed

7.2 For injection rod

The injection rod air cylinder drives the injection rod up and
down. The injection speed can be adjusted by rotating the flow
control screw (Fig. 15) clockwise to increase the speed and
counterclockwise to decrease the speed
Main Air Cylinder Flow Control
Injection Rod Flow Control
8

EMERGENCY STOP

In case of an emergency, the mixing operation can be stopped at
any time by pressing the EMERGENCY STOP BUTTON, (Fig 2, 10).
After problems have been fixed, the machine can be restart by
pulling and turning the emergency button counter clockwise. The
mix cycle will start from the beginning.
MODE
PRESSURE
ACTIVATE
MIX
CYCLE
SAFE TO
MOTOR
RUN
Figure 15.0 Side View
17
9

TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSE
No power input
Emergency button is
Unit fail to start
pressed
Safety door is not
fully closed
No power input
LCD does not light
Insufficient air
pressure
Air Cylinder does not
Air hoses not
move
plugged in
Regulator defective
The hardener is not
Air cylinder is
completely injected
damaged
Injection rod is dirty
The injection rod does
Injection rod is bent
not retract
Not enough mixing
cycle
Material is not
Insufficient air
completely mixed
pressure
Insufficient air
pressure
Cartridge holder is not
Air hoses not
in "Home" position
plugged in
Extension spindle is
not installed for 6"
Mixing rod does not
rod
reach spindle
Mixing rod in not fully
extend
Plunger air hose is
No pressure on
not connected
plunger
Wrong plunger disk
Plunger disk does not
size
fit inside cartridge
Sensor and magnet
Cartridge holder
is not aligned
remains in the down
position during mixing
cycle
No power to motor
Motor is not running
Motor burned out
CORRECTION
Check power cord
connections
Turn Emergency
button clockwise to
release
Closed safety door
Check power cord
connections
Check Fuse
Turn on power
Increase air supply
pressure to 80 psi
Check air connection
Replace regulator
Replace air cylinder
Clean rod
Replace rod
Increase number of
cycles
Increase air pressure
to 80 psi
Increase air supply
pressure to 80 psi
Check air connection
Install extension
spindle for 6" rod
Extend mixing rod
Connect plunger air
hose
Use correct plunger
disk size
Turn off unit and adjust
sensor / magnet
alignment
Check motor
connection
Replace motor