Setup And Operation; Voltage Selection And Fuse Replacement - TECHCON SYSTEMS TS6500CIM User Manual

Automatic techkit mixer
Table of Contents

Advertisement

Available languages

Available languages

8.

SETUP AND OPERATION

WARNING: This unit is equipped with a voltage selector switch. Please check to
make sure the voltage selector is set to match the voltage input.
8.1

Voltage Selection and Fuse Replacement

1.
Select the proper voltage by sliding the voltage switch up or down
Voltage Range
100V – 120V
220V – 240V
Fuse Replacement: The unit is shipped with the fuse installed. If fuse
needs to be replaced please follow instructions below
2.
Remove the fuse holder by using a flat head screw driver to pry it open.
3.
Insert correct fuse into the fuse box, refer to table above
4.
Re-install the fuse holder into the unit
VOLTAGE
SELECTOR
SWITCH
Voltage Setting
115V
230V
FUSE
HOLDER
SCREW
DRIVER
Figure 6.0 Fuse Installation
Fuse Rating
2 Amp, Type F
2 Amp, Type F
FUSE
HOLDER
11
FUSE HOLDER
WITH FUSE
INSTALLED
FUSE

Advertisement

Table of Contents
loading