Turn On The Unit - TECHCON SYSTEMS TS6500CIM User Manual

Automatic techkit mixer
Table of Contents

Advertisement

Available languages

Available languages

1.
Place the wrench on the motor shaft (beneath the spindle).
2.
Place a screw driver between the two locking pins of the spindle.
3.
Hold the wrench and turn the screw driver counter clockwise to unscrew the
spindle assembly.
4.
Remove the spindle assembly from the motor shaft.
5.
Install the spindle extension on the motor shaft by turning it clockwise.
6.
Install the spindle assembly on the spindle extension by turning it
clockwise.
8.4

Turn On the Unit

Caution: Make sure the correct fuse has been installed and the correct
voltage has been set. Refer to section 8.1 for instructions.
1.
Insert the power cord to the power socket (Fig. 3, 20).
2.
Connect the air filter assembly to the air inlet (Fig. 3, 21).
3.
Connect the air hose to the air filter assembly .
Caution: The air filter assembly (7091-9080), supplied with the unit, must be
installed to ensure proper air filtration.
AIR FILTER
4.
Set the air Pressure to 80 psi (5.5 bar) minimum.
Rotate the air pressure regulator knob (Fig. 2, 9) clockwise to increase the
air pressure.
Rotate the air pressure regulator knob counterclockwise to decrease the air
pressure.
Figure 9.0 Air and Power Connection
13
POWER CORD

Advertisement

Table of Contents
loading

Table of Contents