Service Instructions
Service Instructions
Single- and Two-Stage Engine Air Cleaners
Single- and Two-Stage Engine Air Cleaners
e Filter
asten or unlatch the
vice cover. Because
filter fits tightly over the
et tube to create the critical seal, there will
some initial resistance, similar to breaking
seal on a jar. Gently move the end of the filter
k and forth to break the seal then rotate while
ing straight out. Avoid knocking the filter
inst the housing.
a safety filter, replace it every third primary
e the safety filter as you would the primary
cover the air cleaner outlet tube to avoid any
t dropping into the engine.
Surfaces of the Outlet Tube
the Vacuator™ Valve
ipe the filter sealing surface and the inside of
minant on the sealing surface could hinder an
se leakage. Make sure that all contaminant is
ew filter is inserted. Dirt accidently transferred
let tube will reach the engine and cause
turers say that it takes only a few grams of
e! Be careful not to damage the sealing area
Wipe both sides
of the outlet
tube clean.
Inner edge of the
outlet tube
equipped with a Vacuator Valve
sically squeeze to make sure the
inverted, damaged or plugged.
e Old
Leak Clues
ld filter for any signs
ust on the clean side
e sign. Remove any
installing new filter.
Inspect the New Filter for Damage
Inspect the New Filter for Damage
Inspect the new filter carefully, paying attention to
the inside of the open end, which is the
sealing area. NEVER install a damaged
filter. A new Donaldson radial seal
filter may have a dry lubricant on the
seal to aid installation.
Insert the New Radial Seal Filter Properly
Insert the New Radial Seal Filter Properly
If you're servicing the safety filter, this should be seated into
position before installing the primary filter.
Insert the new filter carefully. Seat
the filter by hand, making certain it is
completely into the air cleaner housing
before securing the cover in place.
The critical sealing area will stretch
slightly, adjust itself and distribute the sealing pressure evenly. To
complete a tight seal, apply pressure by hand at the outer rim of
the filter, not the flexible center. (Avoid pushing on the center of the
urethane end cap.) No cover pressure is required to hold the seal.
NEVER use the service cover to push the filter into place! Using the
cover to push the filter in could cause damage to the housing, cover
fasteners and will void the warranty.
If the service cover hits the filter before it is fully in place, remove
the cover and push the filter (by hand) further into the air cleaner
and try again. The cover should go on with no extra force.
Once the filter is in place, secure the service cover.
Caution
Caution
NEVER use the service cover to
NEVER use the service cover to
push the filter into place! Using
push the filter into place! Using
the cover to push the filter in could
the cover to push the filter in could
cause damage to the housing, cover
cause damage to the housing, cover
fasteners and will void the warranty.
fasteners and will void the warranty.
Check Connectors for Tight Fit
Check Connectors for Tight Fit
Make sure that all mounting bands, clamps, bolts, and connections
in the entire air cleaner system are tight. Check for holes in piping
and repair if needed. Any leaks in your intake piping will send dust
directly to the engine!