M A T E R I A L S A F E T Y D A T A S H E E T
Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988
Manufacturer/
The Lincoln Electric Company
Supplier:
22801 St. Clair Avenue
Cleveland, OH 44117-1199
(216) 481-8100
I M P O R T A N T !
This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal
use of this product are covered by Section V; see it for industrial hygiene information.
CAS Number shown is representative for the ingredients listed. All ingredients listed may not be present in all sizes.
(1)
The term "hazardous" in "Hazardous Materials" should be interpreted as a term required and defined in the Hazards Communication
Standard and does not necessarily imply the existence of any hazard. All materials are listed on the TSCA inventory.
Ingredients:
Titanium dioxides
Iron
Manganese and/or manganese alloys and compounds (as Mn)*****
Magnesium and/or magnesium alloys and compounds (as Mg)
Silicon and/or silicon alloys and compounds (as Si)
Silicates and other binders
Nickel (metal)*****
Fluorides (as F)
Boron alloys (as B)
Niobium alloys (as Nb)
Vanadium alloys (as V)
Carbon steel tube
Supplemental Information:
(*)
Not listed. Nuisance value maximum is 10 milligrams per cubic meter.
PEL value for iron oxide is 10 milligrams per cubic meter. TLV value for
iron oxide is 5 milligrams per cubic meter.
(*****)
Subject to the reporting requirements of Sections 311, 312, and 313 of the
Emergency Planning and Community Right-to-Know Act of 1986 and of
40CFR 370 and 372.
Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See Z49.1 referenced in Section VI.
Product is inert, no special handling or spill procedures required. Not regulated by DOT.
Rev 9/07
Date:
Trade Name:
Sizes:
Supersedes:
For Welding Consumables and Related Products

SECTION I - IDENTIFICATION

SECTION II - HAZARDOUS MATERIAL (1)

SECTION III - HAZARD DATA

12/17/2007
MSDS No.:
UltraCore 712A80 SR
All
5/15/2006
Product Type:
Flux Cored Electrode
AWS:
Classification:
CAS No.
Wt.%
13463-67-7
7439-89-6
7439-96-5
7439-95-4
7440-21-3
1344-09-8
< 0.5
7440-02-0
< 0.5
7789-75-5
< 0.5
11108-67-1
< 0.5
7440-03-1
< 0.5
7440-62-2
< 0.5
7439-89-6
(c)
Value is for manganese fume. Present PEL is 5
milligrams per cubic meter (ceiling value). Values
proposed by OSHA in 1989 were 1.0 milligrams per
cubic meter TWA and 3.0 milligrams per cubic meter
STEL (Short Term Exposure Limit).
(@)
As V
0
fume or dust.
2
5
(CONTINUED ON SIDE TWO)
US-CW730
E71T-1MJ-H8, E71T-9MJ-H8,
E71T-12MJ-H8
TLV
PEL
3
mg/m
mg/m
10
10
15
< 5
10*
10*
< 5
0.2
5 (c)
0.5
10*
10*
0.5
10*
10*
10*
10*
1.5
1
2.5
2.5
10*
10*
10*
10*
.05(@)
.05(@)
85
10*
10*
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UltraCore 712A80 SR and is the answer not in the manual?

Questions and answers

Summary of Contents for Lincoln Electric UltraCore 712A80 SR

  • Page 1 M A T E R I A L S A F E T Y D A T A S H E E T For Welding Consumables and Related Products Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988 SECTION I - IDENTIFICATION Manufacturer/ The Lincoln Electric Company Product Type: Flux Cored Electrode Supplier: 22801 St. Clair Avenue...
  • Page 2 Product: UltraCore 712A80 SR Date: 12/17/2007 SECTION IV - HEALTH HAZARD DATA Threshold Limit Value: The ACGIH recommended general limit for Welding Fume NOS - (Not Otherwise Specified) is 5 mg/m ACGIH-1999 preface states that the TLV-TWA should be used as guides in the control of health hazards and should not be used as fine lines between safe and dangerous concentrations.

Table of Contents