Download Print this page

Hose Connection - Xylem rule Tournament 401C Instruction Manual

Livewell/baitwell pumps

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
ELECTRICAL
Wire: Normal installations require 16 gauge wire.
Polarity: Brown pump wire connects to the positive (+) side of the battery. Black
pump wire connects to the negative (—) side of the battery.
Fuse: Install proper size fuse & holder in the positive (+) brown wire between the
pump and the battery.
500 GPH pumps (Models 401 C, 401 STC, 401 FC)
INSTALL A 3.0 AMP FUSE
800 GPH pumps (Models 403 C, 403 STC, 403 FC)
INSTALL A 5.0 AMP FUSE
1100 GPH pumps (Models 405 C, 405 STC, 405 FC)
INSTALL A 6.0 AMP FUSE
IMPORTANT — THIS PRODUCT SHOULD BE INSTALLED WITH THE RECOMMENDED
FUSE SIZE
Note: Keep all wire connections and joints above highest possible water level. Seal
wire connections with a marine sealant to prevent corrosion.

HOSE CONNECTION

Dual Port Option
Each pump is fitted with an additional 1/2" NPT female port and Hex Plug. This feature
allows you to add your washdown pump without adding another thru-hull fitting.