Seacock applications
Drill a 1" diameter hole through the transom or hull
bottom. If drilling through the transom, make sure the
hole inside the boat is beneath the waterline outside
the boat when the boat is standing still.
Install a thru-hull pickup tube with a filter grate to prevent debris from
entering the seacock and the pump. Use a marine sealant on the flat surface
of the thru-hull where it will be in contact with the outside surface of the boat
and around the threaded tube on both sides of the hull. Install the seacock
and pump using pipe tape or sealant on all threaded connections.
Screw the pump into the seacock until it is hand tight. Do not over-tighten.
If the pump is mounted horizontally, the output must be pointed upward
to allow air to vent.
Raise ring to
allow pump
to rotate
Pump discharge
can rotate 360°