Microwave Movement Sensor
This product is fitted with a microwave movement sensor. Please see below detailed operating instructions.
Technical Specifications:
Operating voltage
220 ~ 240V AC 50/60Hz
Rated load
400W (Capacitive load) 800W (Resistive load)
Stand-by power
≤0.5W
Ceiling mounted
100% / 75% / 50% / 25% / 10%
height: 3m
Sensitivity
Ceiling mounted
100% / 75% / 50%
*
height: 6m
Wall mounted
100% / 75% / 50% / 25% / 10%
height: 2m
Hold-time
5s / 30s / 90s / 3min / 20min / 30min
Daylight sensor
2Lux / 10Lux / 25Lux / 50Lux / Disable
Microwave frequency
5.8 GHz ±75MHz
Transmitting power
1mW Max.
Ceiling mounted
3- 6m (radius )
Detection range
height: 3m
12-15m
Wall mounted
height: 1.5-2m
Detection angle
360
0
(Ceiling) / 120
0
(Wall)
Working temperature
-20
C ~ 60
C
0
0
*
50%, 75%, 100% detection sensitivity is workable when installed at 6m mounting height. Only 10%, 25%
tion signal.
sensitivity is not able to detect mo
Settings:
1. Sensitivity
2. Hold-time
1 2 3
I –100%
I – 5s
100%
II – 75%
II – 30s
III – 50%
75%
III – 90s
IV – 3min
IV – 25%
50%
V – 20min
V – 10%
25%
VI – 30min
10%
Trouble shooting:
Malfunction Cause Remedy
Incorrect light-control setting selected
The light will not come on
Faulty lamp
No power supply
The lamp is always on
Continuous movement in the detection zone
The sensor is not mounted for reliably detecting movement
The lamp is on without any
Movement occurred, but not identified by the
identifiable movement
sensor (Movement behind wall, movement of
small object in immediate lamp vicinity etc.)
The lamp will not work
Rapid movements are being suppressed to minimize
despite movement
malfunctioning or the detection radius is too small.
Care and Safety
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before cleaning.
For further information, please visit https://www.lighting-info.co.uk/95542
V7 18/09/2023
UK Manufacturer: BH17 7BY
EU Manufacturer: Brilliant AG,
Brilliantstrasse 1, D-27442 Gnarrenburg
3. Daylight sensor
4 5 6
7 8 9
I – 2Lux
5s
II – 10Lux
30s
III – 25Lux
IV – 50Lux
90s
V – Disable
3min
20min
30min
*Disable means the daylight sensor does not work. The sensor will turn
on light once motion is detected regardless of ambient light level.
Cause
Remedy
Adjust daylight threshold setting
Replace lamp
Check power to sensor
Check detection area setting
Securely mount enclosure
1. Reduce sensitivity.
2. Check the movement behind walls to avoid
facilities such as water pipe, fan, which
may mis-trigger the sensor.
Check detection area setting
Instruction manual
HeroPro CCT Microwave Emergency
95542, 103940
2Lux
10Lux
25Lux
50Lux
Disable*
www.saxbylighting.com
Need help?
Do you have a question about the HeroPro CCT Microwave Emergency and is the answer not in the manual?