Install Vent System - Maytag MGD8630HC Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Long Vent System Chart
Number of
90° elbows
0
Rigid metal
1
Rigid metal
2
Rigid metal
3
Rigid metal
4
Rigid metal
To determine if your model has a long vent system, refer
to the type code located on the serial number plate in the
inner door well. Example: An electric model would be DALV
– ELE – XXXXXXX-XXX. A gas model would be DALV – NAT –
XXXXXXX-XXX.
NOTE: For long vent systems, use of box/louvered hoods
will improve venting regardless of length.

Install Vent System

1.
Install exhaust hood
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
20
Type
Angled
of vent
hoods
160 ft. (48.8 m)
150 ft. (45.7 m)
140 ft. (42.7 m)
130 ft. (39.6 m)
120 ft. (36.6 m)
12" min.
(305 mm)
12" min.
(305 mm)
2.
Connect vent to exhaust hood
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location using
straightest path possible. Avoid 90° turns. Use clamps to seal
all joints. Do not use duct tape, screws, or other fastening
devices that extend into interior of vent to secure vent,
because they can catch lint.