FlaktWoods STOF AC 190 Installation And Maintenance Instructions Manual

FlaktWoods STOF AC 190 Installation And Maintenance Instructions Manual

Advertisement

Quick Links

STOF ROOF FANS
FIRE SAFETY
AIR MOVEMENT
» SAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS
PART NO. 854842

Advertisement

Table of Contents
loading

Summary of Contents for FlaktWoods STOF AC 190

  • Page 1 STOF ROOF FANS FIRE SAFETY AIR MOVEMENT » SAFETY, INSTALLATION AND MAINTENANCE INSTRUCTIONS PART NO. 854842...
  • Page 2: Table Of Contents

    CONTENTS 1. SAFETY PARAGRAPH SAFETY ATTENTION! Only approved, qualified personnel familiar with the assessment of hazards and risks associated with fans, and with the use of tools and test equipment required to service INTRODUCTION & PURPOSE - GENERAL such fans, should install, operate and maintain the product. STORAGE &...
  • Page 3: Mechanical Installation

    4.1 CONSTRUCTION 4. MECHANICAL INSTALLATION Weather Cowl ATTENTION! Base Unit Where the fan is delivered in a crate (or similar), the crate must be considered as a Inlet Cone protective device only, and must not be used as a lifting aid unless otherwise Impeller indicated.
  • Page 4: Installation With Roof Curb

    4.2 INSTALLATION WITH ROOF CURB 4.3 INSTALLATION ONTO A BASE FRAME USING AN INSTALLATION FRAME Install the gasket (included within items delivered) onto the roof curb. Lift the fan and place it Install the gasket (included within items delivered) onto the base frame. Place the installation onto the roof curb.
  • Page 5: Replacement Of Dsc And Dsm Units

    4.4 REPLACEMENT OF DSC AND DSM UNITS 5. ELECTRICAL INSTALLATION & OPERATION When selecting a unit to replace either a DSC or DSM unit, a mounting frame may be required. When selecting a unit to replace a DSC or DSM unit then a mounting frame may be required. Details below show mounting frame requirements.
  • Page 6: Maintenance

    6. MAINTENANCE 7. FAULT FINDING ATTENTION! NOTE! No work should be attempted before completely isolating the fan assembly and its The routine maintenance procedures detailed in Paragraph 6, and Table 1, of this controls from all electrical supplies. In addition, please ensure that all rotating parts of document are designed to help keep the fan operational and fault free.
  • Page 7: European Machinery Directive 2006/42/Ec

    9. EUROPEAN MACHINERY DIRECTIVE 2006/42/EC TABLE 1 (1.7.4.2 CONTENTS OF THE INSTRUCTIONS) ROUTINE EVERY 3 EVERY 6 EVERY 12 COMMENTS MAINTENANCE MONTHS MONTHS MONTHS (CLAUSE C) SCHEDULE Please see a typical example of an EC declaration of conformity certificate (below), which Examine Remove any material/dirt build-up.
  • Page 8: Wiring Diagrams Figures

    STOF 190 EC 1PH WIRING DIAGRAMS STOF 225 EC 1PH WIRING DIAGRAMS STOF 310 EC 1PH STOF 355 EC 1PH STOF 400 EC 1PH OPTION A SDPV - 230 SET TO 0-10 FIGURE 6 FIGURE 7 FIGURE 9 SDPV -230 FIGURE 10 EA002107 STOF AC 1ph 190, 225, 310, 355...
  • Page 9 ® ® all over the world to deliver high quality and energy efficient solutions. Fläkt Woods Limited, Axial Way, Colchester, Essex, CO4 5ZD tel: 01206 222 555 website: www.flaktwoods.co.uk » See global website for international sales offices www.flaktwoods.com...

Table of Contents